Ort der Herkunft |
Guangdong China (Mainland) |
Marke |
SKG |
Modell-Nummer |
AT908-CD401 |
Nutzung |
Industrie |
Theorie |
Temperatur Controller |
AT908 CD series temperature controller AI508 Self-diagnosis function. Free 4-digit measurement value setting. Every parameter can be shielded. Various inputspecification are available, including thermocouple, thermal resistance and linear signal etc.. Adopting modular structure output mode. Multiple output modular specifications are available, which can adapt to different application. Adapting intelligent PID control arithmetic without over adjust. The controller still has auto-tuning function. Be applicable with universal AC 85 256V SMPS or DC 24V power supply. Pre-setting emendation system (for input specification) inside. Freely switch between different input specifications. (various thermocouple, thermal resistance, linear signal etc..) High accuracy and stable control effect. Technical parameter: Model AT908-CD401External dimension W*H*D/(mm) 96* 48* 90Perforate dimension W*H(mm) 92* 45Display units Twin 4-digit LED display, range -1999 9999 (display range is free setting)Scale and control precision Accuracy: 0.3 grade; Control deflection :±1 digit; Internal measurement correction ±100yard; Precision: 0.1°C for K .E. T. N. J. Cu50. Pt100 ; 0.001 for pressure, weight, water levelControl effect (available) F: PID reverse adjust (for heating); D:PID positive adjust(for refrigeration); Transmitter outputInput signals (available) Thermo-couple: K.E.J.S.B.T.R.N; Thermo-resistance: Pt100. Cu50 ; Linear signal: 0 20mv,0 60mv,0 100mv,0 500mv,0 5V,1 5V,0 10V,0-10mA,4-20mA etc.Module for main output L2, L1/L4, K1,K3, K5, X, G, W1 (explanation refers to the following)Module for AUX L2, L1/L4, L5, K1, K5, X, G, W1, V12/V24/V5, SAuxiliary output channel 1 4auxiliary output channel(s)Alarm channel 1 4 alarm channel(s)Alarm types A: Lower deviation alarm B: Higher deviation alarmH: Higher limit alarm L: Lower limit alarm etc.Power supply Universal AC 85 265V (50/60Hz) SMPS or DC 24VPower dissipation ≤5WWork condition Temperature :-10 50°C,Humidity ≤85% no caustic or magnetic field interference Output module explanations: Module types Photo Module name Description Relay module L1/L4 Large capacitance relay (normally-open) contact switch output module (resistance capacitance absorb ) (capacitance: DC30V/2A, AC250V/2A, suitable for output control) L2/L3 Relay normally-open and normally-close contact switch output module (capacitance: DC30V/2A, AC250V/2A, normal type) L5 Dual normally-open contact switch output module (capacitance: DC30V/2A, AC250V/2A, suitable for alarm) Voltage module G SSR output module (DC 12V/30mA time proportional output) V24/V12/V5 Isolated DC V24/V12/V5 voltage output, with maximum current of 50mA, can supply power for outer sensor/transmitter/other circuit. Electric current module X Programmable linear current output module SCR module W1 SCR non-contact constant-open output module (capacitance: AC 100 240V/0.2A ‘not easy to burned’) K1 Single-phase SCR zero crossing trigger output module K3 Three-phase SCR zero crossing trigger output module K5 Single-phase SCR phase-shifting trigger output module Communication module S Isolated photoelectric power supply, RS485 communication module