AI-508-Serie Preiswerter Temperaturregler

AI-508-Serie Preiswerter Temperaturregler

Xiamen, China
Produktionskapazität:
1000 Stück / Tag
Xiamen, China
Firma
86-592-2632373
Vera Lin
Kontaktperson

Basisdaten

Nutzung Industrie
Theorie Temperatur Controller
Ort der Herkunft Fujian China (Mainland)
Marke Yudian
Modell-Nummer AI-508
Economical Intelligent Temperature Controller 0.3%FS ± 0.1°C (0 Decimal) Designed for the industries like plastic machinery, food machinery, packaging machinery, baking Main Features: - The implementation of artificial intelligence control algorithm with auto tuning function eliminates the overshooting problem the standard PID algorithm has, improves the control precision.- Various thermocouples and RTDs inputs are available. With built-in non-linear graduation tables, digital calibration and auto zeroing technology, improves the measurement accuracy and stability.- Advanced modular structure, various optional output modules, shortens the delivery time and reduces the maintenance complexity.- universal 100 240VAC power supply.- ISO9001, ISO14001 and CE compliant, world-class in safety, quality and anti-noise ability.Model Code LegendThe type of AI-508 is made up of 5 partsPart 1 Part 2 Part 3 Part 4 Part 5 Series Size OUTP ALM AUX AI-508 A/B/C/D/D2/E/F L1/L4/G/W1/K1/K3 N/L1/L2/L5 N/L1/L2/L5 Part1: Basal functionAI-508 economical artificial intelligence temperature controller- Input type: K, S, R, E, J, N, and Pt100- Measurement range : K(0 1300°C), S(0 1700°C), R(0 1650°C), E(0 800°C), J(0 1000°C), N(0 1300°C), Pt100(-200 600°C)- Measurement accuracy : 0.3%FS±1°C- Temperature display resolution : 1°C- Control mode: On-off control mode or Artificial Intelligence control with auto tuning.- Output mode (modularized): L1, G, W1, K1, K3 modules are selectable- Alarm: High limit and deviation high alarm.- Power supply voltage rating: 100-240VAC, -15%, +10%; 50-60Hz.- Power consumption : ≤3W.- Ambient : Temperature of -10 60°C, humidity of 0 90RH%Part2: Front panel dimension:SIZE Front Panel Cut-out Dimension Depth Behind Width*Height Width*Height Mounting A 96*96MM 92*92MM 100MM B 160*80MM 152*76MM 100MM C 80*160MM 76*152MM 100MM D 72*72MM 68*68MM 95MM D4 48*48MM 45*45MM 95MM E 48*96MM 45*92MM 100MM F 96*48MM 92*48MM 100MM Part3 & Part4 & Part5: Selectable modules: Part3: Main Output (OUTP) L1: Relay output module (Rating: 2A/250VAC, normally open contact with arc eliminating function) L4: Relay output module (Rating: 2A/250VAC, compact size, normally open contact with arc eliminating function) G: SSR voltage output module (30mA/12VDC) W1: TRIAC, normally open discrete output module, suitable for AC contactors up to 80A, low EMI emission and long lifespan. K1: Single-phase thyristor zero crossing trigger output module. (can trigger three-phase of TRIAC, a pair of inversely parallel connected SCRs or TRIAC power module of current 5-500A) K3: Three phases thyristor zero crossing trigger output module. (Can trigger three-phase of TRIAC, a pair of inversely parallel connected SCRs or TRIAC power module of current 5-500A) Part4: Alarm Output (ALM) N: no module installed L1: Relay contact output module (Rating: 2A/250VAC, normally open contact with arc eliminating function, support AL1 alarm output) L2: Relay contact output module (Rating: 1A/250VAC, compact size, support AL1 alarm output) L5: Output module of dual normally open relay output (Rating: 2A/250VAC, support AL1 and AL2 alarm output) Part5: Auxiliary output (AUX) N: no module installed L1: Relay contact output module (Rating: 2A/250VAC, normally open contact with arc eliminating function, support AL1 alarm output) L2: Relay contact output module (Rating: 1A/250VAC, compact size, support AL1 alarm output) L5: Output module of dual normally open relay output (Rating: 2A/250VAC, support AL1 and AL2 alarm output) Note1: For instrument of dimension D4, because of its compact size, when L1 or L5 module is installed in the ALM socket, L1 would not be able to be fit into theOUPT socket, but L4, which is smaller, could be installed instead.Note2: K3 could not be installed in instruments with dimension D or D4. There is no ALM socket in D2 instruments. L5 module could not be installed in theALM socket of instrument with dimension D.

Lieferbedingungen und Verpackung

Packaging Detail: STNDARD EXPORT CARTON Delivery Detail: IN 3 WORKING DAYS AFTER ORDER CONFIRMATION
Hafen: Xiamen

Zahlungsbedingungen

Letter of credit

Telegraphic transfer

Western Union

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung