Ort der Herkunft |
Zhejiang China (Mainland) |
Marke |
Kripal |
Modell-Nummer |
UKC1 |
Strom Geben |
AC |
Anzahl der Pole |
3 |
Phase |
3 |
SpecificationModelUKC1-9UKC1-12UKC1-18UKC1-22UKC1-32UKC1-40Rated operational currentIe max AC-311A13A18A22A32A40AIe AC-125A25A40A40A50A60ARated operational voltage690VPole No.3P,4PRated operational power in AC-3220/240V2.5KW3.5KW4.5KW5.5KW7.5KW11KW380/400V4KW5.5KW7.5KW11KW15KW18.5KW415/440V4KW5.5KW7.5KW11KW15KW22KW500V4KW7.5KW7.5KW15KW18.5KW22KW660/690V4KW7.5KW7.5KW15KW18.5KW22KWThermal overload relaysclass 10A0.1…22A0.1…22A0.1…22A0.1…22A4…40A4…40Aclass 20A1.16…22A1.16…22A1.16…22A1.16…22A4...40A4...40A ModelUKC1-50UKC1-65UKC1-75UKC1-85UKC1-100UKC1-125UKC1-150UKC1-180UKC1-220Rated operational currentIe max AC-355A65A75A85A105A125A150A180A220AIe AC-180A100A110A135A150A150A200A230A260ARated operational power in AC-3220/240V15KW18.5KW22KW25KW30KW37KW45KW55KW75KW380/400V22KW30KW22KW45KW55KW60KW75KW90KW132KW415/440V25/30KW30KW22KW45KW55KW60KW75KW90KW132KW500V30KW33KW37KW55KW55KW60KW90KW110KW132KW660/690V33KW33KW37KW45KW55KW60KW90KW110KW132KWThermal overload relaysclass 10A7…85A7…85A7…85A7…85A34...125A34...125A34...150A65…240A65…240Aclass 20A7…85A7…85A7…85A7…85A34...125A34...125A34...150A65…240A65…240A ModelUKC1-330UKC1-400UKC1-500UKC1-630UKC1-800Rated operational currentIe max AC-3330A400A500A630A800AIe AC-1400A500A700A1000A1600ARated operational power in AC-3220/240V100KW110KW147KW200KW220KW380/400V200KW250KW295KW400KW450KW415/440V200KW250KW295KW400KW450KW500V200KW250KW355KW400KW450KW660/690V200KW250KW355KW450KW475KWThermal overload relaysclass 10A200…630A200…630A200…630A200…630A800Aclass 20A200…630A200…630A200…630A200…630A800A Auxiliary contacts for 9-32A,1NC and 1NO instantaneous incorporated in the contactors, with add-on blocks common to the whole; Auxiliary contacts for 40-150A, range comprising up to 4N/C or N/O instantaneous, up to 1N/O+1N/C time delay and up to 2N/O or N/C protected contacts and 2 screen continuity terminals; Normalizing Electric is a leading automatic industrial equipment supplier, integrating scientific research, manufacture and trade. TypeUKC1-6MUKC1-9MUKC1-12MUKC1-16MRated current at AC3 (A)691216Rated working current (Ie)A57.510Conventional thermal current(Ith)A16202020AC-3 Use Group220V1.52.234Control Power KW380/415V2.245.57.5440/500V3455.5660V3444Rated working voltage (Ue)V380 660Rated insulation voltage (Ui)V690AC-3Electrical life (times)1million(6Ie Ie)Operation frequency h-11800AC-4Electrical life (times)0.2million(6Ie Ie)Operation frequency h-1300Mechanical life1200