HH61 MCB Miniature circuit breakerac dc MCB HH61 Construction and FeatureProtection against both overload and short circuit High short-circuit capacity Conta
HRB4-32. RCBO onemodule residual current circuit breaker(RCBO
schneider MCB Leitungsschutzschalter HCB-100H 1PMini Circuit Breaker/mcb/circuit breaker HCB-100H 2PMini Circuit Breaker/mcb/circuit breaker HCB-100H 3PMini Circuit Breaker/mcb/circuit b
Circuit Breaker HCB16-63 1p Mini Circuit Breaker/mcb/circuit breaker HCB16-63 2p Mini Circuit Breaker/mcb/circuit breaker Specification and feature: 1. Protection ag
FI-Schutzschalter HCL3-63Residual current circuit breaker/earth leakage circuit breaker(elcb)/RCCB: 1. Type: Electronic & Electromagnetic. 2. Residual current char
Schutzschalter HBB-160S MCCB/moulded case circuit breaker/breaker HBB moulded case circuit breaker is one of the most advanced tyoe breakers in the world, which ado
Hochspannungs-Vakuum-Leistungsschalter
Outdoor-HV Vakuum-Leistungsschalter Outdoor H.V. Vacuum Circuit Breaker Overview: Outdoor H.V. Vacuum Circuit Breaker is a high voltage switch equipment used inthe distribution system o
Eine Art Fehlerstromschutzschalter 1.Function 1)Atypeleakagecurrentprotect 2)ItcanprotecttheACleakage,andtothelagvoltage0°,90°,135°,±DC6mA,thatistosaywhatincludingt
12KV Außen vaccuum Schutzschalter ZW6-12 Series outdoor HV vacuum breakers, 3P,50hz,12KV, can be with fuse protection
MOTOR Schutzschalter (MSS) 3VU,3VE,GV SERIES MOTOR PROTECTION CIRCUIT BREAKER HAS THE ADVANTAGES OF COMPACT FRAMEWORK,SMALL SIZE,LIGHT WEIGHT,HIGH BREAKING CAPACITY AND LONG WO
NF-Zertifikat: Fehlerstromschutzschalter (A t The item is in accordance with standards of IEC., applying to the circuit of AC50/60Hz, 240V single phase, 415V three phases and below it for industr
Elektro / Magnetic FI-Schutzschalter Conforming to VDE 0664,IEC61008 standards, these breakers are applicable for use with AC 50 / 60Hz, 240V single phase or 415V three phase circuits fo
Einstellbare Stromschutzschalter (RCBO) It can be easy to adjust rated current as per Customer's Request. Rated current:5 15A; 10 30A; 30 60A Rated Leakage Current: 300MA; 500MAPole:2Pole;
NEU: Einstellbare Fehlerstromschutzschalter (RCBO Rated current: 5 15A; 10 30A; 15 45, 30 60A Rated leakage current: 100MA,300MA; 500MA Pole: 2 poles; 4 poles NDF series breaker can been adjusted ra
Leitungsschutzschalter (10KA) DISJONCTEUR INDUSTRIEL ET DOMESTIQUE: Features: 1) Mini circuit breakers are mainly suitable for avoiding overload and preventing short circuits 2)
Fehlerstromschutzschalter (RCBO) Conforming with IEC898-87 and IEC755 standards, DZ47L and C45L earth leakage or 60Hz, with single-phase rated voltage of 240V, 3-phase rated voltage
Verkaufen Leitungsschutzschalter (NL7) 10KA Main technical parameters:Miniature Circuit Breaker(MCB) 1) Rated current of frame class (inm): 6 63A 2) Rated voltage (Ue): 240 3) Pole:1,2,3,4 4) B
MCB, ELCB, ISOLATOR Series MCB,ELCB,Insolator is one kind of series, it can been assembled on one distrition box with busbar..
Verkaufen Fehlerstromschutzschalter (RCBO) The BNM small scaled hig disjunction leakage circuit breaker,is developed by our company,it with short circuit protection and over load protection an
SCHUTZSCHALTER TC,TL mini circuit breaker is mainly suitable for avoiding overload and short circuit. It is especially used in illumination and distribution system
Schutzschalter The NID RCCB S residual current devices provide the functions of isolation, switching and earth leakage protection of electrical circuits. They have
DISJONCTEUR DZ47-63 mini circuit breaker is mainly suitable for avoiding overload and short circuit. It is especially used in illumination and distribution syste
Ministromunterbrecher Main technical parameters:1) Rated current of frame class (inm): 63A2) Rated voltage (Ue): 50 / 60Hz, 230 / 400V3) Rated current (In): 1, 2, 4, 6, 10
Ministromunterbrecher C60N mini circuit breakers are of the advanced 1990s level, instead of the older DZ47 (C45N) generation.These breakers have functions for preventing
Circuit Breaker (MCCB) Moulded case circuit breaker, is suitable for the circuit of AC 50Hz (or 60Hz), rated insulation voltage 660V, rated operating voltage under AC 660V,
Circuit Breaker S series moulded case circuit breaker, is suitable for the circuit of AC 50Hz(or60Hz), rated insulation Voltage 660V, rated operating Voltage under A
Screw-Leistungsschalter S101 These breakers are suitable for use in AC / DC 32A and below 50Hz electric circuits up to AC 380V and DC 250V respectively.Used for protection agains
Isolator (neue Ausführung) Having superior dynamic-heating abilty,it is mainly used as a main switch for both terminal assembly electric equipment case, and illumination assemb
Mini-Leistungsschalter C65N The basic norms and main technical parameters1.Shell aircraft rated current level lnm: 63A 2.Rated voltage Ue: 230V/400V AC 3.Rated current In: TypeC
Mini-Leistungsschalter NW The basic norms and main technical parameters1.Shell aircraft rated current level lnm: 63A 2.Rated voltage Ue: 230V/400V AC 3.Rated current In: TypeC
Mini-Leistungsschalter C45 The basic norms and main technical parameters1.Shell aircraft rated current level lnm: 63A 2.Rated voltage Ue: 230V/400V AC 3.Rated current In: TypeC
Mini-Leistungsschalter The basic norms and main technical parameters1.Shell aircraft rated current level lnm: 63A 2.Rated voltage Ue: 230V/400V AC 3.Rated current In: TypeC
Mini-Leistungsschalter L7 The basic norms and main technical parameters1.Shell aircraft rated current level lnm: 63A 2.Rated voltage Ue: 50Hz230V/400V 3.Rated current In: Type
ZW8-12G Vakuum-Leistungsschalter Rated Voltage (KV)12 Rated Current (A)630 Breaking Current (KA)12.5/16/30 Rated Peak withstand current (KA)31.5/40/50 Rated frequency (Hz)50 We can p
ZW32-24 Vakuum-Leistungsschalter Rated Voltage (KV)12 Rated Current (A)630 Breaking Current (KA)16 Rated Peak withstand current (KA)40Rated frequency (Hz)5
VS1-Leistungsschalter All parts are made ourselves. High quality, competitive price. We are the supplier of DELIXI Electric LTD and CHINT Group Corp
ZN85 Schutzschalter 1.High quality, competitive price. 2.Made by our own factory. 3.high voltage DC Circuit breaker 4.Certification: ISO9001Features: Rated Voltage (K
ZW7 All parts are made ourselves. High quality, competitive price. We are the supplier of DELIXI Electric LTD and CHINT Group Corp.It is used for indoor
Trennschalter HL/H7 Rated Voltage(V) Rated current of trips (A) Compliance with standard 1 pole: 250V 16, 20,32, 40, 63, 100 IEC408 IEC609-1 BS5419 VDE0660 2,3,4 p
Fehlerstromschutzschalter ModelRated Current (A) Rated voltage (V) Rated Operating Current (A) Residual Operating Current range Rated conditional short circuit current Mechani
Getriebeschalter Gear Switch Unit Short time withstand current (r.m.s. Amps for 1 second) Short circuit making capacity (Peak Amps at 415V AC) Rated fused short-circu
Fehlerstromschutzschalter Structure and working principle This series of leakage circuit breakers, mainly by electronic leakage circuit breakers zero sequence current transfor
Durable sichere Fehlerstromschutzschalter Product specifications and parameters Basic specifications and parameters 1 leakage circuit breakers biggest break time see table 1 I train making ti
Fehlerstromschutzschalter Applicable scope Applicable to ac rated voltage isolator, to 380V and rated current - 16 630A circuit, as personal leakage protection devices of th
Fehlerstromschutzschalter Table 1 note: 1 listed in table 1 specification, but according to the users in a circuit breaker in table 1 shall not exceed the specified in each pr
Wirtschaftlich Fehlerstromschutzschalter Applicable scope DZ20LE series leakage circuit breakers (hereinafter referred to as the leakage circuit breakers) is a current movement type electron
Fehlerstromschutzschalter Applicable scope DZ15 series plastic shell circuit breaker (hereinafter referred to as the breaker) is suitable for use in ac rated voltage isolator,
Fehlerstromschutzschalter Applicable scope Applicable to ac rated voltage isolator, to 380V and rated current - 16 630A circuit, as personal leakage protection devices of th
Wirtschaftlich Fehlerstromschutzschalter Table 1 note: 1 listed in table 1 specification, but according to the users in a circuit breaker in table 1 shall not exceed the specified in each pr