Ort der Herkunft |
Shandong China (Mainland) |
Marke |
BOS |
Modell-Nummer |
BNSG |
Größe |
1000*800*2060 |
Gewicht |
900kg |
Eingangsspannung |
450Vdc to 820Vdc |
Ausgangsspannung |
380vac |
Ausgangssignals Frequenz |
50hz/60hz |
Ausgangsstrom |
245A |
Ausgangstyp |
dreifach |
Geben |
DC/AC-Wechselrichter |
50kw solar grid tie inverter Technical Features: Adopt U.S TI company control DSP chip. Using Mitsubishi or Infineon company IGBT module to improve the reliabity. MPPT(Maxium Power Point Tracking)Technology. With a manually input DC breaking switch,manually breaking switch from AC power grid . With advanced anti-island inspection scheme and perfect monitoring function. With overload,short circuit,abnormal grid protection,and alarm fuctions. Wide input DC range,the efficiency up to 98%. Adapt large grid voltage fluctuation characteristics,normal working of the grid connected inverter allows voltage range of threephasekine voltage:350VAC 430VAC,Frequency range:47 51.5Hz. User-friendly operation interface,English menu,can display the operationg data,real-time fault data,historical fault data,and the status of equipment. Can provide including RS485/RS232 or Ethernet remote communication interface.RS485 follow the Modbus communication protocol;Ethernet interface support TCP/IP protocol,support to obtain dynamic(DHCP) or static IP address. Peovide isolation transformer and transformerless types. Stand compiled: EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-6-4,EN61000-3-2,EN61000-3-3,EN60164-1-1,En55022,EN50178 TypeBNSG50KS IsolationLow frequency transformers Max. DC power 55KWp Max. DC input voltage 880Vdc PV voltage range ,MPPT 400Vdc to 880Vdc Max. number of strings (parallel) 8 Max. input current 137.5A Nominal AC output power 50KW Max. AC output power55KW THD of AC current <3% (nominal power) Power factor>0.99 Max. efficiency96% Euro efficiency94% Nominal AC voltage (three to phase)310VAC to 450VAC Nominal AC frequency50Hz/60 Hz Internal power consumption an night<100W Automatically put into operation conditionsWhen the DC input and power grids meet to the requirements, the inverters automated operation Automatic restart time5min (time adjustable) ProtectionPossess the protecting function of polarity connecting contrary,short circuit, island effects ,over heat, over load, ground fault Comm. interfaces RS485 Operating Temp. -20 to +40 Relative humidity 0 to 95%,no condensing Altitude(m)less than 2000 meters (More than 2000 meters down the amount to be used) Cooling methodNatural coiling Noiseless than 60dB Protection degreeIP20(Indoor) W×L×H(mm) 800*600*2060 Weight(kg) 700