(LPG) Detektor (Auto-Ventil)

(LPG) Detektor (Auto-Ventil)

Ningbo, China
Ningbo, China
Firma
86-574-62839119
winky li
Kontaktperson

Basisdaten

Ort der Herkunft Zhejiang China (Mainland)
Marke JST
Modell-Nummer JST-A(W)
The gas detector Technical parameters 1.Induced Gas Natural gas,LPG(liquid petroleum gas),Coal gas 2.Power DC12V/AC220V 50HZ 3.Operating Current 50mA-400mA10%LEL 4.Alarm Concentration 10%LEL 5.Buzzer Volume: ≥70db at 1m 6.Operating Condition -10°C +50°C Relative humidity: <90%RH 7.Stability: under long time working condition, the discrepancy ≤±5%LEL 8.Repeatability: repeating alarm tests, discrepancy ≤±5%LEL 9.Alarm Sensitivity , discrepancy: ≤±5%LEL 10.Alarming Pattern: Acousto-optic alarm, Start valve controller, input networking signal 11.Power Consumption: ≤5W Firstly, the necessary testing is to determine the gas is heavier than air or is lighter than air: heavier than air gases are liquefied petroleum gas, etc.; lighter than air gases are natural gas, carbon monoxide, artificial gas, and biogas; Install the alarm in the right place according to the weight of the gas. (Refer to picture 3 on the right). When the gas is heavier than air: The alarm must be mounted over the ground and the height must be more than 31cm, and be away from the gas source within 1.5 meters radius. When the gas is lighter than air: The alarm must be mounted under the ceiling and the height must be less than 31cm, and be away from the gas source within 1.5 meters radius. Fix the mounting plate on the chosen position and then probe the detector into it and to have a check whether it is fastened or not. (Refer to picture4 on the right) (1) More attention should be paid when install it in the household. (2) Close distance to gas stoves is not permitted, in case of the heat of the stove flames. The position with heavy smoke should be avoided too, to prevent the mistaken alarm or the bad ventilation which may affect the sensitivity of the alarm.. (3) The alarm should not be placed around the ventilating fan or the windows or the shower room where the vapor is heavy. The white plug wire is just the AC 220V power cord.(If you use the AC 220V, then you only need the Acousto-optic alarm, there won’t be any red, black, yellow, blue, green wires along with the alarm. And if you use the DC 12V, then there won’t be a AC 220V power cord along with the alarm.) Update Date:2010/11/09 1:44:16

Lieferbedingungen und Verpackung

Packaging Detail: 20 pcs in one carton or according to yourself Delivery Detail: within 30days after receipt of your order
Hafen: Ningbo and Shanghai

Zahlungsbedingungen

Letter of credit

Telegraphic transfer

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung