综合聪明的电磁flowmeter

综合聪明的电磁flowmeter

近湖镇, 中国
生产能力:
1000 单元 / 月
近湖镇, 中国
公司
0086-0517-86951288
Lei Xu
联系人姓名

基本信息

出生地 Jiangsu China (Mainland)
牌子的名字 Meiante
模式的数量 LDE
Integrated intelligent electromagnetic flowmeter Description Electromagnetic flowmeter is induction gauge to measure the volume flow of the conducting object. electromagnetic flowmeter of LDE model, plug-in type is a new pattern Electromagnetic flowmeter that based on tube type electromagnetic flowmeter. It keeps the advantage of of tube type electromagnetic flowmeter and also aims at the difficulties and great expense of installing the tube type electromagnetic flowmeter on the big tubes , according to the NIKURADS theory, measuring the mean flow rate through electromagnetism which finally gets the volume flow of the fluid. Especially after the hot-topping and mounting with pressure techniques being adopted, plug-in electromagnetic flowmetercan be installed without stopping the car or water flow, and it can also be installed in castiron tube, cement tube and PE tube. The plug-in electromagnetic flowmeter provides the measurement of the volume of the flow with a new method Characteristics No moving or resistance parts inside the tube, seldom additional pressure loss in measurement. Results of measurement have nothing to do with flow velocity distribution, fluid-power pressure, temperature, density, viscosity or other physical parameters. Alter the range according to the customers’ requirements on line. High definition LCD display, operation all in Chinese menue , easy to use, simplicity of operation, understandability. Adopt SMD parts and surface paste( SMT circuit is of high reliability) Adopt 16 bit insertion micro processor, high operating rate, high precision, programmable frequency, LF rectangular wave excitation. Degital quantity dispose, high antijamming capability, reliable measurement, high precision, range of the flow measurement can reach 150:1. Ultra-low EMI switch power supply which enables the line-voltage variation in a wide range, great resistance to EMC. Three integrator inside which can discriminability show forward direction accumulative total volume and D-value integrating volume. RS485, RS232, Hart and Modbus digital communicating signal output. Function of self-checking. Summarization 1.operating principle Theory of electromagnetic flowmeter is based on Faraday's electromagnetic induction law. Tube of flowmeter is a kind of lining insulating material, none permeability alloys tube. Two electrode are fixed on the measuring tube along the tube diameter direction through tube wall. The electrode tip is abreast to the lining. When both side impulsing the excitation, magnet exciting coil will produce a operating magnetic field whose density is B through the direction that is vertical to measure tube axis. At this moment, if there’s certain volume of specific conductance fluid going through the measuring tube will incise the magnetic line of force which produce the electromotive force(E). Electromotive force is directly proportional to density B multiply internal diameter of measuring tube(d) and mean flow rate( ).Electromotive force produced from electrode goes through cable and then reach in converter. Converter will show the volume of the fluid and output the pulse, imitate signals of electric current which control and adjust the flow after dispose these signals. E=KBd thereinto:E-----------ignal voltage between electrodes(v) B-----------------------magnetic flux density(T) d-----------------------internal diameter of measuring tube(m) ---------------------- mean flow rate (m/s) k, d are constant, as exciting current is constant current, so B is also constant, from E=Kbd , knowing that fluid volume(Q) is directly proportional to signal voltage(E), and flow velocity induced signal voltage has a linear relation with volume(Q). So, flow(Q) can be confirmed as long as E been measured, this is the basic theory of electromagnetic flowmeter. From E--KBd knowing that, temprature, density, pressure, conductivity, liquid-solid two-phase fluid medium composition of solid-liquid ratio of the measured medium have no effects of the measuring result. So electromagnetic flowmeter is an authentic volume gauge. For the manufacturers and users, any volume flow of conducting flow medium can be measured as long as the common water been practically standardized without any rectification. This is one of electromagnetic flowmeter’s advantages that does not exist in other gauge. There’s no activity and resistance parts inside the measuring tube, so seldom pressure loss exists and its reliability is very high. Application area As electromagnetic flowmeter has its special advantages, it is widely applied in chemical fiber, foodstuff, papermaking, sugaring, mining and metallurgy,water supply and drainage,environmental protection,water conservancy,steel,petroleum,pharmacy,etc. It measures the volume flow of different kinds acid, alkali, saline solution, slurry, ore pulp, pulp,coal-water slurry,corn steep liquor,fiber pulp,grain pulp,lime milk,sewage,cooling raw water,water supply and drainage,saline,aquae hydrogenii dioxidi,beer,different kinds of drink,black liquor,green liquor ,etc.

交货条款及包装

端口: Shanghai

付款条款

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称