出生地 |
Shandong China (Mainland) |
牌子的名字 |
HuaKun |
模式的数量 |
HK100GF |
速度 |
1500/1800rpm |
频率 |
50/60HZ |
额定功 |
100kw |
额定电压 |
400V |
目前的评级 |
180A |
产出种类型 |
AC三个阶段 |
1.silent generator set 2.noise level:below to 65db by 7m distance 3.5 hours test 4.competitive price 5.high standardGenset ModelHK100GFRated Output100KWEngineModelR6105AZLDRated Output110KWCylinderSIXBore*Storke(mm)105*130Typein line,water cooling,4-strokeaspirationnatural aspirationcombustion methoddirect injectiondisplacement(L)6.75fuel consumption(g/kw.h)224cooling methodforced water coolingstarting methodelectrical startlubricathion methodForcedlubricatingAlternatorRated Output100KWrated current180Arated voltage400Vfrequency50HZRated speed1500r/minpower factor0.8connection type3P,4W Specifications: 1) Output range: 8kW (10kVA) - 400kW (500kVA) 2) Noise level: below to 75dB by 7m distance 3) Sound attenuated enclosure: special noise elimination setting restrains the machinery noise and the unit has perfect all-weather service property and the outside steel material features preferable corrosion prevention capability 4) Water-cooled 5) 8hrs operation base tank 6) Key start / auto start 7) Sound-proof / weather-proof canopy is optional 8) 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires alternating current output 9) Frequency: <3% 10) Frequency at stable state: <0.5% 11) Frequency deviation at instantaneous state: ≤+10% 12) Frequency return time: ≤3s 13) Voltage deviation at stable state: ≤±1% 14) Voltage deviation at instantaneous state: ≤+20% 15) Voltage return time: ≤4s 16) Voltage modulation: ≤0.3% 17) Standard configuration of gensets: a) Engine: Deutz, Perkins, Steyr, Cummins and Weichai series diesel engine b) Engine type: water-cooled, in line four-stoke, Humit cylinder liner, direct injection c) Alternator: Marathon brushless alternator 18) Control system: a) Automatic alarm system: the unit has the acoustic-optics alarm system and arrestor for any situation as the start defeat, the water is over temperature, the oil pulls down, over speed, over load and over current b) Operation display: i) Unit voltage, tri-phase load current and frequency display ii) Water temperature, oil pressure display iii) Fuel level, fuel temperature display iv) Audible and visual alarm lamps and buzzers 19) Starting system: DC alternator is used to start engine 20) Short circuit protection: MCCB air switch 21) Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C 22) Filter system: oil, fuel and air filter 23) Accessories: exhaust elbow, bellow, muffler 24) Supply standard collocation: a) Diesel engine with all accessories, 3 filter, electric systems b) Alternator c) Steel structure d) Fan and water tank cooling system e) Flange connector f) 12 / 24V starting motor and charge engine g) Air cleaner, fuel cleaner, oil cleaner h) On-board control panel i) MCCB air conservation switch j) 12 / 24V starting accumulator and Battery line k) Set shock absorber l) High-efficient silencer