出生地 |
Japan |
牌子的名字 |
Konica-Minolta |
模式的数量 |
SPAD502Plus |
权力 |
电子 |
使用 |
汽车测试机器的 |
Name:Chlorophyll Meter Model:SPAD-502PLUS Introduction: 1.Measures leaf chlorophyll, an important indicator of plant health.The SPAD-502Plus performs quick measurementson 2.Non-destructive measurement of plant chlorophyll 3.Enables quick, easy measurement of the chlorophyll content of plant leaves without damaging the leaf. Chlorophyll content is one indicator of plant health, and can be used to optimize the timing and quantity of applying additional fertilizer to provide larger crop yields of higher quality with lower environmental load. 4.Quick, easy measurement of chlorophyll levels in plant leaves without damaging the leaf. Measurements are taken by just closing the measuring head on the leaf. Since the leaf is not cut off or damaged in any other way, the same leaf can be measured as the plant grows. 5.Trend graph display.Up to 30 measurements can be stored in memory and displayed on a trend graph, so that changes in measurements over time can be seen and abnormal values can be noticed at a glance. 6.Water-resistant.The SPAD-502Plus is water-resistant (IPX-4) so it can be used outdoors even in the rain. * It is not immersible, and should not be washed with water. 7.Compact and lightweight for portability.The SPAD-502Plus is small enough to fit in a pocket and weighs only 200g, so it can be taken anywhere. 8.Low power consumption.The SPAD-502Plus uses LED light sources, resulting in extremely low power consumption, with approximately 20,000 measurements from one set of fresh alkaline-manganese batteries. 9.Monitoring of growth and health of plants. The SPAD-502Plus can be used to monitor the growth and health status of a wide variety of agricultural products, including wheat, rice, corn, cotton, etc. 10.Nitrogen fertilization optimization. The SPAD-502Plus can be used for determining when and how much nitrogen fertilizer should be provided to plants. Optimizing fertilization in this way leads to not only greater yields of higher quality, but also results in less over-fertilization, reducing environmental contamination due to the leaching of excess fertilizer into the soil and underground water. Optical density difference at two wavelengths 2 mm×3 mm 1.2 mm maximum 12 mm (with stopper having position adjustable from 0 to 6 mm) 2 LED elements 1 SPD (silicon photodiode) LCD panel showing 4-digit measurement value (values shown to first decimal place) and 2-digit number of measurements; Trend graph of values in memory can also be shown. -9.9 to 199.9 SPAD units Memory capacity for up to 30 values; Calculation/display of average of data in memory also possible 2 AA-size alkaline batteries More than 20,000 measurements (when using new alkaline batteries under Konica Minolta test conditions) Approx. 2 seconds Within ±1.0 SPAD units (for SPAD value between 0.0 and 50.0 under normal temperature/humidity) * added to display when measurement exceeds 50.0 SPAD units Within ±0.3 SPAD units (SPAD value between 0.0 and 50.0 with no change in sample position) 78 (W) ×164 (H) ×49 (D) mm 200 g (excluding batteries)