压力开关

压力开关

原价: 11,00 USD
北景乡, 中国
生产能力:
10000 片 / 月
北景乡, 中国
无名
86-010-51655362
13701089084
Peter Lee
联系人姓名

基本信息

出生地 Beijing China (Mainland)
牌子的名字 Green Island
模式的数量 PS0212A
麦克斯。 目前的 8A
麦克斯。 电压 220Vac
APPLICATION : PS1050A pressure switch is used to detect the pressure of city gas, natural gas, LPG and air etc. When the gas pressure changes, the diaphragm of the pressure receiving part detects it and operates the (SPDT) switch to ON/OFF control of the external electrical circuit. These switches are widely used to detect the upper limit or lower limit pressure of gas or air to be supplied to a gas burner. Model Selection: ModelPressure Range(mbar)nominal operating differential(mbar)Maximum working pressure (mbar)PS0212A2...12<2300PS1050A 10...50<10300 PS3015A 30...150<20500 Technical Data: Dimensions: see Fig.1 Connection: G1/4'' Set point accuracy:15% of the full scale NOTE: the knob readings are approximations of the actual settings. Contact ratings: Resistive load: 220Vac, 5A; Inductive load: 220Vac, 3A; Material of pressure receiving parts: NBR single diaphragm Material of housing:Aluminium die-cast. Ambient temperature range:-15°C - 60°C; Relative humidity:max.90% at 40C(non-condensing) Electrical connection:Plug connection accordingtothree pin plug connector("DIN plug") Sensed medium temperature range: -15°C- 80°C; Enclosure: IP54. Working Principle: The PS pressure switch is used to testing the pressure changing in the gas pipe or air pipe. When the pressure rises, and higher than the set point, terminals between COM and NO is closed, COM and NC opened. When the pressure falls, and low than the set point, terminals between COM and NC is closed, COM and NO opened. The feature of the pressure switch can be used to insure the burner working in the safety station. Installation: – Read these instructions carefully. Failure to follow the instructions could damage the product or cause a hazardous condition. – Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. – The installation has to be carried out by qualified person only – Carry out a thorough checkout when installation is completed. – Electrical installation must be in accordance wth local requirements. Connect the pressure switch onto the pipe: 1. Remove the dust seal from the pressure inlet. 2. Apply a moderate amount of good quality compound to the pipe for fitting only, leaving the end thread. The pipe thread should be G1/4” . Please see fig.1-3 as reference. 3. Screw the pressure switch onto the pipe, using wrench boss incorporated in the housing. 4. Complete the electrical connections as instructed in the electrical connections section. Please see fig.1-2 as reference.

交货条款及包装

Packaging Detail: packaged in cardboard boxes Delivery Detail: 1 week
端口: Tianjin

付款条款

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称