展览的类型 |
只是模拟 |
阶段 |
三阶段 |
出生地 |
Guangdong China (Mainland) |
牌子的名字 |
LDE |
模式的数量 |
DTSD51 HF |
衡量能源的范围 |
2W and 5VA |
准确性的课 |
CL1.0(ACTIVE)/ CL2.0(reactive) |
产出电压 |
3*220/380V3*57.7/100V3*100... |
工作温度 |
-20C to +45C |
面 |
278mm*164mm*78mm(normal) |
1. Summary DSSD/DTSD51 HF Three Phase Static Multi-function Energy Meter is designed according to market demands and international metering standards. It can measure active/reactive energy and max demand in 4 tariffs; record parameters (voltage, current and power etc.) in real time; and monitor meter faults such as voltage loss and current loss etc. It also can read meter via infrared or RS485 port. DSSD/DTSD51 HF Three Phase Static Multi-function Energy Meter conforms to: CEI IEC62052-11-2003 Electricity metering equipment (a.c.) General requirements, tests and test conditions Part 11: Metering equipment CEI IEC62053-21-2003 Electricity metering equipment (a.c.) Particular requirements Part 21: Static meters for active energy (classes 1 and 2) equipment CEI IEC62053-23-2003 Electricity metering equipment (a.c.) Particular requirements Part 23: Static meters for reactive energy (classes 2 and 3) equipment DL/T614-1997 Multi-function energy meterDL/T6451997 Multi-function energy meter communication protocol2. Functions and Features 2.1 Positive and negative active/reactive energy measurement in TOU 2.2 4 time zones, 4 tariffs, 10 time segments and 5 day tables 2.3 Active/reactive max demand measurement, sliding time can be set as required 2.4 Energy data of last two months; Billing data of last 12 months, billing date can be set as required 2.5 Voltage, current, active/reactive power and PF measurement in real time 2.6 Alarm if voltage loss, current loss or reverse phase sequence occurs; events record such as voltage loss, current loss, voltage qualified rate, programming, demand reset, broadcast time synchronization etc. 2.7 Meter programming via PC or HHU with program switch and password protection 2.8 LCD scroll display or display by pushing button/remote infrared controller 2.9 Pulse testing output and 1Hz clock output 2.10 Independent infrared port and RS485 port with less mutual interference when communicating, RS485 baud rate can be set within 1200∼9600bps 2.11 Waking up the meter by Infrared port or button to realize meter reading under no energy 2.12 Energy freezing in real time or at 0:00 3. Technical Specifications Item Technical Parameters Rated voltage 3×220/380V, 3×57.7/100V, 3×100V Basic current 1.5(6)A,3(6)A,5(20)A,10(40)A,15(60)A,20(80)A,30(100)A Frequency 50Hz Accuracy CL1.0(active); CL2.0(reactive) Power burden Voltage circuits≤2W and 5VA Current circuits≤2.5VA Normal operation temperature -20∼+45 Limit operation temperature -30∼+60 Relative humidity ≤85% RTC accuracy(daily error) ≤0.5S (23) Communication protocol DL/T645-1997 or custom Dimension 278mm´164mm´78mm(normal) 328mm´164mm´78mm (long terminal cover) Weight About 1.9kg