出生地 |
Guangdong China (Mainland) |
牌子的名字 |
SOROTEC |
模式的数量 |
GP9335C 120-800KVA |
体重 |
900-7000KGS |
产出电压 |
380/400/415V |
Telecom Online UPS GP9335C 120-800KVA (Telecom UPS)1) Rated at 0.9 output power factor, more applicable to server computer and networkcenter that use PFC technology in a large scale, and deliver more Active power thanconventional UPS2) Advanced distributed active parallel technology can realize parallel operation of 6 UPSunits without the need of centralized bypass cabinet3) 6-inch extra large LCD that display 12 language( Chinese .English.Russian.Spanish.French…)4) The efficiency of the machine is more than 94%, and reach 98% in ECO mode.5) Use advanced 6th generation DSP and full digital control technologies to realize highersystem stability6) Intelligent battery management maintains battery automatically to prolong thebattery life7) Standard input/output filter improves the system EMC performance8) Layered independently-sealed ventilation channel and redundant fanGP9335C Series Technical Specifications: ModelGP9335CRectifier Type6p12p6p12p6p12p6p12p6p12pRated Nominal 120KVA/108KW 160KVA/144KVA 200KVA/180KW 300KVA/270KW400KVA/360KWRated input voltage 380/400/415VAC 3-phase 4-wireRated frequency 50/60HZInput parameters Input voltage range ±25%Input frequency range 45Hz 65HzInput soft start function 0-100% 5-300settableInput power factor >0.98(If harmonic filter is added)Input harmonic current (THDi) ‹4.5%(If harmonic filter is added) Bypass Bypass voltage range -20% +15%Bypass frequency range 50/60HZ±10%Output parameters Inverter output voltage 380/400/415VAC 3-phase 4-wireVoltage stability ±1%(Steady status),±3%(Transient status)Frequency 50/60Hz Mains power synchronization window ±5%Actually measured frequency accuracy (internal clock)50/60Hz±0.01HzOutput power factor 0.9(Output 90kW per 100kVA)Transient response time <5msInverter overload capability At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s Short circuit current from inverter3ph 1.5ln for 5seconds,1ph 2.9ln for 5secondsMaximum Bypass capability1000% for 100ms Phase shiftcharacteristicWith 100% balanced load <1°With 100% imbalance load <1° Total harmonicDistortion(THDv)100% linear load <1%100% non-linear load <3%System efficiency (full load) Up to 94% (inverter efficiency is up to 98%)Rectifier output parameters Charger output voltage stability 1%DC ripple voltage ≤1%Operating environment Operating temperature range 0 40°CStorage temperature -25 70°C(Without battery)Relative humidity 0 95% No condensationNoise (1m) 58-68dBProtection level IP20Standard Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3