出生地 |
Beijing China (Mainland) |
牌子的名字 |
EPSOLAR |
模式的数量 |
EPRC-ST-MT |
EPRC-MTis designed for solar DC lighting system.There are several optional working modes including Light ON + Light OFF control mode, Light ON +set time OFF delay mode, Test mode, and general mode.DC output mode and two time setting modes Digital LED display shows the40 lighting options(by switch with 5 seconds ) A brief description follows below: 0 Test mode, lights on after it detects no light, lights off after it detects light. 1 Light is on for 4 hours after sundown 2 Light is on for 5 hours after sundown 3 Light is on for 6 hours after sundown 4 Light is on for 7 hours after sundown 5 Light is on for 8 hours after sundown 6 Light is on for 9 hours after sundown 7 Light is on for 10 hours after sundown 8 Dusk-to-Dawn, light is on all night 9 Lights remain turned off, ON/OFF mode 10 Light is turned on for 2 hours after sundown, turned off, and turned on for 1 hour before sunrise 11 Light is turned on for 2 hours after sundown, turned off then, and turned on for 2 hours before sunrise 12 Light is turned on for 2 hours after sundown, turned off then, and turned on for 3 hours before sunrise 13 Light is turned on for 2 hours after sundown, turned off then, and turned on for 4 hours before sunrise 14 Light is turned on for 2 hours after sundown, turned off then, and turned on for 5 hours before sunrise 15 Light is turned on for 3 hours after sundown, turned off then, and turned on for 1 hours before sunrise 16 Light is turned on for 3 hours after sundown, turned off then, and turned on for 2 hours before sunrise 17 Light is turned on for 3 hours after sundown, turned off then, and turned on for 3 hours before sunrise 18 Light is turned on for 3 hours after sundown, turned off then, and turned on for 4 hours before sunrise 19 Light is turned on for 3 hours after sundown, turned off then, and turned on for 5 hours before sunrise 20 Light is turned on for 4 hours after sundown, turned off then, and turned on for 1 hours before sunrise 21 Light is turned on for 4 hours after sundown, turned off then, and turned on for 2 hours before sunrise 22 Light is turned on for 4 hours after sundown, turned off then, and turned on for 3 hours before sunrise 23 Light is turned on for 4 hours after sundown, turned off then, and turned on for 4 hours before sunrise 24 Light is turned on for 4 hours after sundown, turned off then, and turned on for 5 hours before sunrise 25 Light is turned on for 5 hours after sundown, turned off then, and turned on for 1 hours before sunrise 26 Light is turned on for 5 hours after sundown, turned off then, and turned on for 2 hours before sunrise 27 Light is turned on for 5 hours after sundown, turned off then, and turned on for 3 hours before sunrise 28 Light is turned on for 5 hours after sundown, turned off then, and turned on for 4 hours before sunrise 29 Light is turned on for 5 hours after sundown, turned off then, and turned on for 5 hours before sunrise 30 Light is turned on for 6 hours after sundown, turned off then, and turned on for 1 hours before sunrise 31 Light is turned on for 6 hours after sundown, turned off then, and turned on for 2 hours before sunrise 32 Light is turned on for 6 hours after sundown, turned off then, and turned on for 3 hours before sunrise 33 Light is turned on for 6 hours after sundown, turned off then, and turned on for 4 hours before sunrise 34 Light is turned on for 6 hours after sundown, turned off then, and turned on for 5 hours before sunrise 35 Light is turned on for 7 hours after sundown, turned off then, and turned on for 1 hours before sunrise 36 Light is turned on for 7 hours after sundown, turned off then, and turned on for 2 hours before sunrise 37 Light is turned on for 7 hours after sundown, turned off then, and turned on for 3 hours before sunrise 38 Light is turned on for 7 hours after sundown, turned off then, and turned on for 4 hours before sunrise 39 Light is turned on for 7 hours after sundown, turned off then, and turned on for 5 hours before sunrise MODEL NO: EPRC-ST-MT 12 VOLT or 12/24 VOLT auto work,10 AMPS Regulation point: 14.4 Volt Low voltage disconnect: 11.1 Volt Low voltage Reconnect: 12.5 Volt Self-consumption: 6mA maximum Electronic protections Terminals: for wire sizes to 6 mm2 Type of Charging: series PWM Temperature: -35C to +55C Weight: 250g Dimension: 140x90.5mm Compliance: CE