This Side-spray sterilizer iswidely used for the high-temperature sterilizatin in foodstuff,beverage,can,medical needle etc. *Specialized in sterilization and cooking test on any packing products. *Suitable for trial run of a small batch product*Especially Applied in flexible pouch or box product. Full automatic control system Manufacture and design standard:GB150-1998This autoclave applys PLC programmable to control. Which controls the whole process of heating,insulation and cooling.Automatically record the pressure, temperature, control the water level.Self-equipped small water storage case, recycles condensate water in steaming heating for the use of sterilizing water,Preventingfurring in heat exchange.This retortinstalls quick-open door safe interlock system.Main technical parameterSpecificationDN 800x L750Outline specification1900mmx1400mmx1400mmBasket Size750mmx500mmx50mmNumbers of Basket8 pcsTrolley1 pcFull Volume of Inner Chamber:0.51m3Material304Matching Boiler Min. Steam Consumption500kg/hCompressed Air Supply Pressure0.6MPaSteam Supply Pressure0.5MPaCool Water Supply Pressure0.3-0.5MPaMax.W.Pressure0.3MPaMax.W.Temperature143 Degree CelsiusHot Water Circulating Pump Power2.2kWHot Water Circulating Pump Flux7t/hHot Water Circulating Pump Head30.3mWater Supply Pump Power2.2kWWater Supply Pump Flux12t/hWater Supply Pump Head28mDiameter for Steam InletDN20Steam Consumption per Potaround 60kg/hSteam Flux(heating process)around 450kg/hCirculating Water Flux(sterilizing process)around 130L/potCompressed Air Consumptin1.3m3/potControl Box Power0.15kWNet Weight2t Customer-made is available.