solenoid valve for ammonia and freon, water oil ga

solenoid valve for ammonia and freon, water oil ga

原价: 20,00 USD
松江乡, 中国
生产能力:
500 片 / Day
松江乡, 中国
初学者
86-21-67728816-825
Leo Chen
联系人姓名

基本信息

港口的规模 3mm 3.5mm 4mm
出生地 Shanghai China (Mainland)
模式的数量 ADF
牌子的名字 STF
标准或Nonstandard 标准
结构 飞行员
压力 高压
权力 螺旋管
材料 不锈钢的
solenoid valve for ammonia and freon Features: 1.Coil of this type is hermetic by plastic.It features moisture proof,anti-viberation,and anti-corrosive.All parts are made by stainless steel.It can be used for ammonia and Freon refrigerating system,pneumatic hydraulic and water supply system. 2. suitable for HFC,HCFC refrigerants and Ammonia; clean water ;</=viscosity machine oil 3.Coil type: AC:24V 36V 110V 220V DC: 12V 24V 110V 200V 4:opening pressure diff: AC: 0.05----21bar DC:0.05-17bar 5:Max working pressure :30bar 6:working range:---25°Ccentigrade to 100°C Operating principle ADF series solenoid valve is pilot type valve.When energized the coil,it lead a magnet and pick up plug,open the small orifice,course to pressure in upside of valve reduced.So the pres sure difference happen both side of diaphragm. The pressure difference lift diaphragm to open the main Orifice.When main orifice open,dia phragm shouldnt drop even if pressure difference both side of diaphragm exist too,because of flow inertia function.When coil deenergized,plug drop to close small orifice because of reset spring. Media flow to upside of valve through throttle orifice.Then balance pressure both side of diaphragm,so diaphragm return to close the mail valve. Installation: 1.The valve must install in horizontal pipe line under vertical position. The flow direction must be meet the arrow direction in valve boby. 2.Installing position should be low viberation. 3.Must install filter before solenoid valve in order to prevent block throttle port and lead to no function. 4.The coil input power must meet rated input power showed on the label. 5.System operating pressure must be meet open valve pertormance. 6.Departure coil from valve when en ergized in coil is limited in order to avoid damage the coil. 7.According to valve with manual function.It must turn manual bar to open the vaNe bemre doing system air tightness, in order to avoid to damage diaphragm.

交货条款及包装

Packaging Detail: normal package Delivery Detail: within 15 days
端口: FOBshanghai

付款条款

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称