出生地 |
Zhejiang China (Mainland) |
牌子的名字 |
MW(reverse osmosis membrane 8040 LE... |
模式的数量 |
BDX8040B-ULP |
BDX8040B-ULP LE reverse osmosis membrane is used for the desalination of low salinity water and other similar water and it has high desalination rate and long time stable performance under high flow and low operating pressure (fall 20-40% compared with common low pressure membrane). BDX8040B-ULP ro membrane is applicable to the water which contains less than 2000ppm salt. It is used to produce pure water or ultra pure water in electronics, power, petrochemical, food, beverage and pharmacy. ModelBDX8040B-ULPCapabilityMaterialsPA(polyamide)Average Salt Rejection%99.5(99.0)Permeate Flow gpd(m3/d)9500(36.0)Error±15%Active Membrane Area ft2(m2)375(35.0)Testing ConditionsStandard Solution1500 ppm NaClOperating Pressure psi(Mpa)150(1.05)Recovery Rate of Single Membrane Element15%Temperature deg C25PH Value of Solution6.5-8.5Test TimeRun for 30 minutesLimiting ConditionsMax. Feedwater Temperature deg C45Max. Operating Pressure psi(MPa)600(4.12)Max. Feedwater Flow gpm(m3/h)75(17.0)Max. SDI of Feedwater5Max. NTU of Feedwater1Concentration of Free Chlorineppm< 0.1PH Value Range of Feedwater as Continuous Operation2-11PH Value Range of Feedwater as Chemical Cleaning1-11Max. Pressure Difference of Single Membrane Element psi(MPa)13(0.09)The minimal proportion of single membrane element's conc. press to perm. flow5 : 1