出生地 |
Guangdong China (Mainland) |
牌子的名字 |
YADA |
模式的数量 |
YDD-COS |
Model description and parameter: 1) Example: YDD-COSφ-V2-A2-P2-C2-05 2) Name: YDD single-phase power factor transducer 3) Input voltage: 220V 4) Input current: 5A 5) Auxiliary supply: AC 220V±15% 6) Measuring range: 0.5 (C) ∼ 1 ∼ 0.5 (L) 7) Output range: DC 0 ∼ ±5V Ordering instructions: When ordering, please check type, input range, auxiliary power supply , COSφ range and output range according to the above table and the actual need. Performance indexes: 1) Standard: GB/T 13850-1998idtIEC688:1992 2) Accuracy: 0.5% 3) Whole power consumption: ≤5VA 4) Working stability: per year< 0.2% 5) Working frequency withstand voltage:AC2.0kV/min.1mA 6) Insulation resistance: ≥20MΩ (DC 500V) 7) Response time: ≤300ms 8) Input range: AC 0 ∼ 6A, AC 0 ∼ 380V, frequency 50 / 60Hz 9) Absorbing power: <0.5VA / 450V, <0.2VA / 100V, <0.1VA / 5A 10) Overload ability: a) Current: 2 times continuum, 30 times/s b) Voltage: 2 times continuum 11) Output signal: DC 0 ∼5V, 4 ∼ 20mA, 12 ∼ 20mA 12) Load resistance: a) Current output: RL≤600Ω b) Voltage output: RL≥2KΩ 13) Working condition: -10 ∼ 50oC, 20% ∼ 90% 14) Storage condition: -40 ∼ 70oC, 20% ∼ 95% 15) Installation mode: DIN (35mm) guide apparatus and fixation by M4 screw