出生地 |
Beijing China (Mainland) |
牌子的名字 |
procet |
模式的数量 |
PT-PSE801G-T |
poe Features and functions PROCET PT-PSE801G-T is an eight ports concentrated network long-distance power supply implement, fit with IEEE802.3at standard, can work regularly between input voltage 100VAC 280VAC.This power supply use super type 5 cable to connect with network terminal equipment, is suitable for 10/100 /1000M network environment. ModelPT-PSE801G-TSystem reliabilityMTBF>100k hoursNo. of Ports8 PortTemperature-15°C +55°CRelative humidity5% 90%RHInput voltage100VAC 280VAC,47Hz 63HzMaximum output power300WOutput voltage regulation accuracy-48VDC±2%Load regulation-48VDC±1%Dimensions268(W) x44 (H) x210 (D) mmWeight<3kgDC output voltage of broadband noise3.4kHz 150kHz≤50mv 0.15MHz 30MHz≤20mvRange of output over-voltage protection-52VDC -50VDCOver-temperature protection>100°COver-current protection(Single circuit)750Ma 800MaOver voltage protectionInput voltage >290VAC 310VACOver voltage recovery pointInput voltage > 285VACUnder voltage protection<85VAC 90VACUnder voltage recovery point<100VACSafety ApprovalsCE,RE,EN55022,CLASSB Discrete noise voltage 3.4KHz 150KHz≤5mv 150KHz 200KHz≤3mv 200KHz 500KHz≤2mv 0.5MHz 30MHz≤1mv Ethernet ports light instructions Red light POWER on:Show power working normally Green light ACTIVE on: show equipment supply power normally Green light in network port is on and then off after several seconds show overload protection or short circuit. Red light shining slightly in use shows feed part of the network port is off-loads, can judge there is a glitch of the power supply or far-end equipment. Installation and Commissioning 1. Insert the input power line into 110--220VAC introducing input socket. 2. Connect output signal line respectively 3. Connect communicating & introducing line, signal wire, output lines tightly to avoid bad contacts and loose. Note: Item 1: The installation site must be away from heat source and electromagnetism interference source, non-corrosive gas and metal dust. Item 2:Mustn’t block the cooling hole of the equipment. Item 3: Installation must be stable fixed placing, not a violent shock. Item 4: Note whether the AC input voltage is during the range of 100VAC 280VAC. Item 5: Prevent to crash and conflict with other equipment during the installation, so as not to cause local damage of the machine surface. Boot Test 1.Using resistance gears of millimeter to detect Ac input, short circuit phenomena did not exit; after loading, green light in output interface is on shows output normally. If it is off after several seconds shows short circuit and limited flow phenomena did exit. 2. After electric communication, the working light in front board is on. Daily maintenance and maintenance: Long-distance power supply PROCET PT-PSE801G-T can work uninterruptedly,to guarantee the reliability of the power supply, must prepare daily maintenance work, make the power system in the best working state. 1. Clean power source regularly to prevent dirt retention phenomenon 2. Check whether the connecting line of input and output is loose or contact undesirable, if damaged, please change in time. Storage: When storing, must be kept in dry warehouse, not exposure to sun and rain. Storage temperature:-5°C +55°C (low temperature storage recovery time is at least 4 hours), Relative humidity:5% 90%RH