出生地 |
Jiangsu China (Mainland) |
牌子的名字 |
ChangFeng |
模式的数量 |
KVV |
导体材料 |
铜 |
绝缘材料 |
聚氯乙烯 |
Plastic insulated control cable(contain:fire resistant,flame retardant,halogen free low smoke etc.) KVV Copper conductor PVC insulated PVC sheathed control cable KVVP Copper conductor PVC insulated PVC sheathed control cable with braided shield KVVP2 Copper conductor PVC insulated PVC sheathed control cable with copper tape shield KVV22 Copper conductor PVC insulated PVC sheathed control cable with steel tape armour KVV32 Copper conductor PVC insulated PVC sheathed control cable with steel wire armour KVVR Copper conductor PVC insulated PVC sheathed flexible control cable with shield KVVRP Copper conductor PVC insulated PVC sheathed Flexible control cable with braided shield ZR-KVV Copper conductor PVC insulated PVC sheathed flame retardant control cable ZR-KVVP Copper conductor PVC insulated PVC sheathed flame retardant control cable with braided shield ZR-KVVP2 Copper conductor PVC insulated PVC sheathed flame retardant control cable copper tape shield ZR-KVV22 Copper conductor PVC insulated PVC sheathed flame retardant control cable with steel tape shield ZR-KVV32 Copper conductor PVC insulated PVC sheathed flame retardant control cable with fine steel wire armour ZR-KVVR Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable ZR-KVVRP Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable with braided shield KVVRP1 Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable with spiral shield KVVRP3 Copper conductor PVC insulated PVC sheathed flame retardant control flexible cable with PVC-Aluminum complex shield 1. Applications 1 Rated voltage U0/U should be 450/750 V 600/1000V U0 Valid value of the voltage between main insulated conductor and earthing (metal shield, metal sheath of environment dielectric). U valid value of voltage between any two phases conductor in multicourse cable or single core cable system. When AC. System is applied, the rated voltage of cables should be at least equal to the nominal voltage of the system. When DC. System is applied; the nominal voltage of this system should not be more than the rated voltage of the system by 1.5 times. 2 The permitting long-term operating temperature of cable conductor should be PVC insulation: 70 Chemical Sioplascable: 90 Irradiation XLPE :105 135 3 The installing temperature of cable should not be less than 0. Recommending permitted bending radius: Non-armored cable: not less than the overall diameter f cable by 6 times Shielded flexible cable: not less than the overall diameter of cable by 6 times