出生地 |
Guangdong China (Mainland) |
牌子的名字 |
apc |
模式的数量 |
1000 |
Online UPS powerNOTE:SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE OR OPTIONAL SMART SLOT ACCESSORY CARDS FUNCTION FACTORY DEFAULT USER SELECTABLE CHOICES DESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 days (168 hours), On Startup Only,No Self-Test This function sets the interval at which the UPSwill execute a self-test. UPS ID UPS_IDEN Up to eight characters to define the UPS Usc this field to uniquely identify the UPS,(ie.server name or location) for network management purposes. Date of last Battery replacement Manufacture date Date of Battery Replacement mm/dd/yy Reset this date when you replace the batterry module. Minimum Capacity Before Return from Shutdown 0 percent 15,30,45,50,60,75,90 percent The UPS will change its batteries to the specified percentage before return fron a shutdown. Voltage Sensitivity The UPS detects and reacts to line voltage distortions by transferring to battery operation to protect the connected equipment. Where power quality is poor,the UPS may frequently transfer to battery operation.If the connected equipment can operate normally under such conditions,reduce the sensitivity setting to conserve battery capacity and service life. High Medium low Brightly lit:UPS is set to high sensitivity(default). Dimly lit:UPS is set to medium sensitivity. Off:Low battery warning interval is about eight minutes. To change the UPS sensitivity,press the voltage sensitivity button(rear pane).Use a pointed object(such as a pen) to do so. You can change the sensitivity level through PowerChute software. Alarm Control Enable Mute,Disable User can mute an ongoing alarm or disable all existing alarms permanently. Shutdown Delay 90 seconds 0,180,270,360,450,540,630 seconds Sets the interval between the time when the UPS receives a shutdown command and actual shutdown. Low Battery Warning. PowerChute interface software provides automatic,unattended shutdown when approximately two minutes(by default) of battery operated run time remains. 2 min. 5 min. 8 min. Brightly lit:Low battery warning interval is about two minutes. Dimly lit:Low battery warning interval is about five minutes. OFF:Low battery warning interval is about eight minutes. Psossible interval settings:2,5,8,11,14,17,20,23 minutes. The low battery warning beeps are continuous when two minutes of run time remain. To change the warning inerval default setting,press the voltage sensitivity button(use a pointed object such as a pen to do so),while pressing and holding the Test button(front panel). Synchronized Turn-on Delay 0 seconds 60,120,180,240300,360,420 seconds The UPS will wait the specified time after the return of utility power before turn-on(to avoid branch circuit overload). High Transfer Point 230V models:253VAC 120V models:127VAC 100V models:`108VAC 230V models: 257,261,265VAC 120V models: 130,133,136VAC 100V models: 110,112,114VAC To avoid unneccessary battery usage,set the high transfer point highter if the utility voltage is chronically high and the connected equipment is known to work under this condition. Low Transfer Point 230V models: 208VAC 120V models: 106VAC 100V models: 92VAC 230Vmodels: 196,200,204VAC 120V models: 97,100,103VAC 100V models: 86,88,90VAC Set the low transfer point lower if the utility voltage is chronia\cally low and the connected equipment can tolerate this condition. Output Voltage 230V models: 230VAC 230V models: 220,240VAC 230V models ONLY,allow the user to select the output voltage.