KYN61-40.5KV/35KV Metal-Clad Switchgear

KYN61-40.5KV/35KV Metal-Clad Switchgear

北景乡, 中国
北景乡, 中国
无名
86-10-67668022
87697121
87694425
Yuzhou Wang
联系人姓名

基本信息

出生地 Beijing China (Mainland)
牌子的名字 Huadong Electric
模式的数量 KYN61-40.5
Model KYN61-40.5KV clad withdrawal type AC metal-enclosed switchgear (hereinafter referred to as switch cabinet) is applicable to three phase AC 50HZ, 40.5KV single bus and single bus section electric power system, is mainly used for accepting and distributing electric energy in power transformation and distribution of power plant, substation, industrial and mining enterprise and high-rise building. It also could control, protect and monitor the circuit, meet requirement of IEC 60298, GB3906 and DL404 etc standards, and has perfect, five preventions function. Product features 1. Adopt thermal shrinkage insulation material and epoxy coating insulation technique, shape of electric pole is optimized, cabinet structure is compact, has small floor area. 2. Switch cabinet body adopts high quality cold-rolled steel sheet and passes CNC plate work processing and shaping, then is connected via high intensity bolt, nuts and rivet nuts, surface of structural member adopts spraying plastic or galvanization technique. 3. It may work with domestically produced ZN85-40.5(3AV3) vacuum circuit breaker and French Schneider SF1, SF2 type and Alston FP series SF6 circuit breaker to meet requirements of different customers. 4. All function cubicles of switch cabinet adopt metal baffle plate to isolate, independent pressure release channel is also provided. 5. Circuit breaker and earth switch etc could be operated in case switch cabinet door is closed, that is to say operation is permissible when door is closed. 6. Structure of switch cabinet has strong adaptability, there are more than 198 main wiring schemes to meet requirements of different customers. 7. Mechanical interlock device is provided between cart, circuit breaker, earth switch and rear cabinet door to protect against maloperation, five preventions function is complete, safe and reliable. No. Item Unit Parameter 1 Rated voltage KV 40.5 2 Rated frequency Hz50 3 Rated current of main bus A 1250, 1600, 2000 4 Rated current of branch busA 630, 1250, 1600 5 Rated insulation level 1 min power frequency withstand voltage (effective value) KA Phaseto Phase, Phase to earth Primary isolating fracture 95 115 Lightning impulse withstand voltage (peak value) 185 215 Auxiliary control circuit 1 min power frequency withstand voltage V 2000

交货条款及包装

賣家沒有明確指定交貨條件。 有關更多信息,請聯繫賣家。

付款条款

Letter of credit

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称