出生地 |
Sichuan China (Mainland) |
牌子的名字 |
Zhengfang |
模式的数量 |
KVVP |
导体材料 |
铜 |
绝缘材料 |
聚氯乙烯 |
Scope of ApplicationThe control cable are suitable for the wiring of electrical controlling equipments and instrument, monitoring and controlling return circuit, electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.Type& Specification(Partly)Type Name Section Area(mm2) No. of Core Application SiteKVV Copper Conductor, PVC Insulated and Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors, in cable ditches or pipes4 6 2-1410 2-10KVVP Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors, in cable ditches or pipes where shielding is required4 6 2-1410 2-10KVVP2 Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable 0.75 1.0 1.5 2.5 4-10 Permanent installation indoors, in cable ditches or pipes where shielding is required4 6 7-6110 4-10KVV22 Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors, in cable ditches, Be able to withstand stronger external mechanical force4 6 4-1410 4-14KVVR Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are requiredKVVRP Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable 0.5 0.75 1.0 4-61 Installation indoors where flexibility shielding and movability are required1.5 2.5 4-48KYJV Copper Conductor, XLPE Insulated and PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors, in cable ditches or pipes4 6 2-1410 2-10KYJVP Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors, in cable ditches or pipes where shielding is required4 6 2-1410 2-10KYJV22 Copper Conductor, XLPE Insulated, Steel-tape Armoured, PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors, in cable ditches, pipes or underground Be cable to with stand stronger external mechanical force4 6 4-1410 4-104.Service Conditions(1) The long-time working temperature of conductor of PVC insulated cable is 70oCThe long-time working temperature of conductor of XLPE insulated cable is 90oC(2) The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D