JMJC-一个多功能小组局的错探测器

JMJC-一个多功能小组局的错探测器

徐州市, 中国
生产能力:
100 片 / 世纪
徐州市, 中国
公司
86-516-89207388
Lili Wang
联系人姓名

基本信息

出生地 Jiangsu
牌子的名字 JIANGMEI
模式的数量 JMJC-A
1. Usage and the Application Range The JMJC-A multi-functional substation detector is an instrument mainly for the function detection, maintenance and overhaul of the safety monitoring system. The instrument can be used to check the substation for all the safety monitoring systems, and it is a multi-functional auxiliary tool provided for the maintenance personnel of the safety equipment in the coal mine, the application of the instrument shall ensure that the maintenance personnel of the safety equipment quickly calibrate the functions, the operating condition and the failure condition of the sub-station. 2. Product Features (1) Digital display: various measurement data is displayed in the digital meter, and the display is clear and direct, with high accuracy. (2) Simple operation: the equipment has few operating pushbutton and turn-buttons, the operation is simple, the utilization is convenient, and it is easy to control the equipment. (3) Provision of the required power supply for the normal operation of the substation: the JMJC-A multi-functional substation detector provides a direct current constant voltage power supply with the continuously adjustable voltage output of 0 to 30 V, to ensure that the detected substation works normally. (4) Over-voltage, over-current and short-circuit protection: when the output voltage/current exceeds a certain range, the power supply shall cut off automatically to ensure the safety of the detection substation. (5) Operating voltage and current display: while supplying operating power for the substation, the equipment displays the operating voltage and current of the substation. (6) Two-way independently adjustable analog signal output: two-way independent analog signals shall be provided at the same time, and the frequency is adjustable in an extensive range. Each way can independently output different frequencies through the knob adjustment, and it can also simulate the analog signals such as air velocity, methane, CO, etc.. Simultaneously, the output shall also be taken as the detection signal source of other equipment. (7) Two-way signal output of independently adjustable switching value: the switch value signals are two-way independent current signals, the adjustable range is the constant milliamp current of 0 to 100 mA, and the accuracy is high. The critical point of on and off switching value of the substation shall be determined with accurate measurement during the detection of the substation. The current measured through the milliamp current meter is low, and the output is stable, so it can be used to detect other equipment. (8) Achievement of detection of the locking function of air-door, electricity and methane at the sub-station: the detector shall provide the output of multi-analog signals and of multiplex switch signals; one way for methane simulation, one way for air velocity simulation, in combination with another way for the output of switch value, so the detection of the locking function of air-door, electricity and methane at the substation shall be realized. (9) Various complete and flexible operating methods: each output signal shall be used either independently or integrally. The various output of the detector are led out through the general wiring board, so that the user can connect different connectors according to his own needs, to different substations and other equipment, thus to realize detection and calibration of the substations of various manufacturers, without replacement of hardware, therefore, the utilization is very convenient. (10) Communication between sub-station and system: the parameters such as the baud rate of the communication between the measuring sub-station and the computer, the peak-peak value of the voltage/current of the communication signal, etc. shall be measured by firstly connecting the interface to the sub-station, and then to the computer. 3. Main Technical Specifications 1. Operating voltage: AC 220 V±10%/50 Hz 2. Test range of frequency: 0 to 10000 Hz 3. Output milliamp current: 0 to 100 Ma, and the accuracy: 0.1 mA. 4. Output direct current operating voltage: 0 to 30 V ±10% 5. Output direct current operating current: <1.5 A. 6. Operating mode: long-time continuous operation.

交货条款及包装

Packaging Detail: Foam inner packing, carton outer packing Delivery Detail: 10days

付款条款

Telegraphic transfer

MoneyGram

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称