High ESP Concealed Ducted Fan Coil Unit

High ESP Concealed Ducted Fan Coil Unit

中国
生产能力:
200 片 / Day
中国
初学者
86-0760-23973815
Tony Tong
联系人姓名

基本信息

出生地 Guangdong China (Mainland)
ModelFC-24L1WAA-800HFC-30L1WAA-1000HFC-36L1WAB-1200HFC-42L1WAB-1400HFC-48L1WAC-1800HFC-60L1WAC-2000HElectric DataPower supply220V 240V/50H/1 PHMax Input PowerW30044477877810001222Max. current(1)A1.42.03.53.54.55.6Physical DataTotal Cooling Capacity at High Fan Speed(2)3 RowsBtu/h230002900035500415005190058200W67408260101101180015200170504 RowsBtu/h285003620044000513005810065000W83501028012510145901702019040Sensible Cooling Capacity at High Fan Speed3 RowsBtu/h170002100025500297003810042600W498061507470870011160128404 RowsBtu/h202002500030200352004260047600W592073208850103101248013940Nominal Airflow Rate at High Fan SpeedCfm8009401180147017702000m3/h135016002000250030003400Cooling CoilFin heightinch121212141416mm305305305356356406Fin lengthinch303642424848mm7629141067106712191219Face areaft22.503.003.504.084.675.33m20.230.280.330.380.430.50Max. working Pre.2Mpa---20 kgf/cm2FanTypeForward Multi-vane Centrifugal Ventilator Direct DriveModel/Qty8"×7-1/2"/18"×7-1/2"/28"×7-1/2"/2.MotorTypeMultispeed Asynchronous MotorQty111111Output Power(2)W130200350350450550External Static PressurePaNominal : 150PaNominal : 150PaNoise Level(3)LowdB(A)<38<39<41<41<42<42Medium<39<40<42<42<44<44High<41<43<44<44<46<46Coil Circuits1 Row6667782 Rows6667783 Rows6667784 Rows66671416Chilled Water Connnection Pipe1/2/3 Rows1/2"FPT--3/4"MPT3/4"FPT--1"MPT4 RowsDrain PipeInchG3/4Net dimension(W×D×H)mm1220×742×4101370×742×4101523×742×470Packing Dimension(W×D×H)mm1345×755×4201400×755×4201550×755×480Net Weight2 rowskg38.544.154.958.568.972.83 rowskg40.846.858.162.072.977.34 rowskg43.149.561.365.576.981.8Shipping Weight2 rowskg42.549.160.964.575.979.83 rowskg44.851.864.168.079.984.34 rowskg47.154.567.371.583.988.8Optional FWS Under Power Supply: 208 230V/60Hz/1Ph, 115/60Hz/1Ph, 100 110V/50Hz/60Hz/1Ph. *The dimension of the unit exclude draim pan.Notes : (1) The currents are under the voltage of 220V. (2) The motor output power may be revised according to the actual external static pressure drop. (3) Noise Level is tested 1 meter away from the air outlet point in the ARI standard acoustic room. (4) Air Entering temperature DB/WB 27/19.5°C,Chilled water Inlet Temperature 7°C and Water temperature increase by 5°C.

交货条款及包装

Packaging Detail: Carton Box Delivery Detail: 30-35Days
端口: shunde

付款条款

Letter of credit

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称