HF-702HC控制单元Genset

HF-702HC控制单元Genset

松江乡, 中国
生产能力:
1000 片 / 月
松江乡, 中国
公司
86-21-37722543
WEI WANG
联系人姓名

基本信息

出生地 Brazil
HFPLC702 Series Automatic Generator Module USER MANUAL Quality power parts, One-stop service! HFPLC702 Auto Start Module - 2 - DESCRIPTION The Model HFPLC702 is an Automatic Engine Control Module. The module is used to automatically start and stop the engine, indicating the operational status and fault conditions, automatically shutting down the engine and indicating the engine failure by LED on the front panel. HFPLC702 append a LCD hours count that base on HFPLC702. OPERATION Operation of the module is via a three position key switch mounted on the front panel with OFF(O), START( ) and AUTO( ) positions. In the O position the output are de-energized. Manual Operation: 1. Select manual run ( ). 2. Depress pre-heat button for required length of time. 3. Press START( ) to crank engine Once the Start button is pressed and maintained, the engine fuel system is energized. The Crank output is then energized and the starter motor operated, disengaging automatically when the engine fires or when the Start button is released. The protection hold-off timer is then initiated. Automatic Operation: 1. Select AUTO( ) 2. When Remote Start is active, the generators will automatic start. Operation of any of the following alarms (which are close on fault) will cause the run output to de-energize: . Low Oil Pressure . High Engine Temperature . Auxiliary Shutdown . Over speed This will remove the fuel supply from the engine and bring it to rest. Each alarm has its own LED indicator and once activated no further alarm conditions will be accepted. The alarm output and relevant LED will remain active until the until is reset by turning the switch to the O position. Over speed Protection HFPLC702 Auto Start Module - 3 - Over speed protection is derived from the generator Hz output. The over frequency circuit monitors the generator Hz output and will shut down the engine immediately if a pre-set frequency level is exceeded. This trip level is selected by a switch for either 50Hz or 60Hz nominal operation (57Hz or 68Hz trip respectively). During engine cranking and for a short time afterwards the protection hold-off timer (10 seconds ) is active and the relevant alarm inputs are inhibited. This enables the engine to start and achieve normal running conditions. Once the timer has expired the inputs are enabled Providing normal protection from the module. Charge Failure warning Charge Failure warning is also provided by monitoring the WL terminal on the charge alternator. This operates on a similar principal to the warning lamp fitted in a motor vehicle, should the output fail the charge fail LED will illuminate. The module will also provide the alternator excitation current via this connection. SPECI F ICATION DC Supply: 8 to 35V Continuous. Alternator Input Range: 15-275 V AC RMS Alternator Input Frequency: 50-60 Hz at rated engine speed. (Minimum 75V AC) Over speed: nominal frequency +14% (+24% Overshoot)

交货条款及包装

Packaging Detail: carton box Delivery Detail: 5-7 days
端口: Shanghai

付款条款

Telegraphic transfer

Western Union

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称