TheseTubes are defined by the reinforcement materials paper, cotton fabric and glass fabric - are characterised by very specific material properties. The different varieties within each product category are manufactured for the purpose of obtaining individual combinations of electrical, mechanical, thermal and chemical properties.
Physical, mechanical and dielectric Preformens for Epoxy Glass tubes with fabrics 1:1No.
IEC 60893-3-2Properties
Units
EP100
EPGC201 G300-1
EP200
EPGC203 G300-1
EP200
EPGC306 G300-1
EP200
EPGC308 G300-1
Standard
Typical
Standard
Typical
Standard
Typical
Standard
Typical
1
Water absorption ( 2mm)
mg
≤ 20
12
≤ 20
15
≤ 20
15
≤ 20
15
2
Flexuralstrength,
Perpendicular to laminations ( lengthwise)
At rom temp.
MPa
≥ 340
350
≥ 340
355
≥ 340
355
≥ 340
355
155°C ±2 °C
≥ 170
280
≥ 170
280
280
3
Impact strength,
parallel to laminations, Charpy, notch
kJ/m²
≥ 33
55
≥ 33
42
≥ 33
42
42
42
4
Electric strength,
perpendicular to laminations ( 3mm )
in transformer oil at 90°C ± 2°C
kV/mm
≥ 11.8
14
≥ 11.8
13
≥ 11.8
13
≥ 11.8
13
5
Dielectric breakdown voltage,
parallel to laminations ( 25 mm )
in transformer oil at 90 °C ±2°C
kV
≥ 35
45
≥ 35
48
≥ 35
48
≥ 35
48
6
Dielectric dissipation factor 48 – 62 Hz
[ tgδ ]
≤ 0.04
0.025
≤ 0.04
0.03
≤ 0.04
0.03
≤ 0.04
0.03
7
Dielectric constant [εr ]
( Dielectric Permittivity )
≤ 5.5
4.9
≤ 5.5
4.9
≤ 5.5
4.9
≤ 5.5
4.9
8
Insolator resistivity after immersion
GΩ
≤5.0*10²
8*10³
≤5.0*10²
6*10³
≤5.0*10²
6*10³
≤5.0*10²
6*10³
9
Comparative tracking index
≥ 600
≥ 600
≥ 600
≥ 600
≥ 600
10
Flammability
11
Temperature Index
≥ 130
130
≥ 155
200
≥ 155
200
≥ 180
200