出生地 |
Japan |
牌子的名字 |
YOKOGAVA |
模式的数量 |
EJA110A |
We supply the following YOKOGAVA Transmitter: 1> EJA110A2> EJA120A3> EJA130A4> EJA210A/220A5> EJA310A6> EJA430A.7> EJA440A8> EJA510A/EJA530A9> EJA11810> EJA43811> EJA11512> EJA213 PRODUCT INFORMATION: The high performance differential pressure transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well as liquid level, density and pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. The EJA Series is available with BRAIN, HART, FOUNDATION fieldbus or PROFIBUS PA communication protocols. FEATURES: -- Excellent performance and stability: The EJA series uses a formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability. -- Compact and light-weight design Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier. -- Fieldbus communication capability Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today. EJA series offers two types of fieldbus models, FOUNDATION fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation. PARAMETERS: EJA110A Differential Pressure TransmitterL CapsuleM CapsuleH CapsuleV CapsuleRange-10 to 10 kPa (-40 to 40 inH2O)-100 to 100 kPa (-400 to 400 inH2O)-500 to 500 kPa (-2000 to 2000 inH2O)-0.5 to 14 MPa (-70 to 2000 psi)Span0.5 to 10 kPa (2 to 40 inH2O)1 to 100 kPa (4 to 400 inH2O)5 to 500 kPa (20 to 2000 inH2O)0.14 to 14 MPa (20 to 2000 psi)Accuracy±0.075%±0.065%±0.065%±0.065%Degrees of protectionIP67, NEMA 4X, and JIS C0920 immersion proofCertificatesFM, CENELEC ATEX, CSA, IECExOutput4 to 20 mA DC, FOUNDATION fieldbus or PROFIBUS PA 2-wire system with digital communicationSupply voltageBRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)Ambient temperature-40 to 85 deg C (-40 to 185 deg F) (general use type) -30 to 80 deg C (-22 to 176 deg F) (with integral indicator)Process temperature-40 to 120 deg C (-40 to 248 deg F) (general use type)Maximum working pressure16MPa(2300psi) 3.5MPa(500psi) for L capsule with special materialsMounting2-inch pipe mountingWetted parts materialCapsuleSUS316L(Diaphragm material is Hastelloy C-276), Hastelloy C-276, Tantalum, MonelCover flangeSUS316, Hastelloy C-276, MonelHousingCast aluminum alloy or SUS316 equivalent stainless steel (optional)