DTSY450 Three Phase Prepaid Static Active Watt hou

DTSY450 Three Phase Prepaid Static Active Watt hou

乐清市, 中国
生产能力:
5000 片 / Day
乐清市, 中国
无名
86-577-62887363
Kelly G.
联系人姓名

基本信息

出生地 Zhejiang China (Mainland)
牌子的名字 ZHIMING
模式的数量 DDS450
准确性的课 2
工作温度 0 degree -45 degree
Three-phase Prepayment Electronic Watt hour Meter for Active Energy, briefly named as three-phase IC card watt hour meter, is used for measuring three-phase AC active energy with rated frequency of 50Hz to realize using electrical energy after prepayment. The product adopts advanced micro-electronic technique to collect, process and memorize data Its technical performances are conform to the requirements of national standards of IEC 61036, GB/T8382-1996. It has advantages of small size light weight and high reliability. Operating principle The meter consists of four main function elements: The first is electrical energy measurement element, the second is control system based on microcomputer, the third is CPU card element, and the fourth is the power supply. The element of electrical energy measurement adopts special large integrated circuit that produces a series of pulse to represent electrical energy consumption and transmits them to micro computer for measurement. The measurement data is saved in the CPU card. The micro computer transmits data to IC card by interface of per-paid IC card to fulfill various functions. The power supply adopts three-phase circuit that works normally in the conditions of one or two phases are missing. Specification Mode Accuracy class Reference Voltage Basic Current(A) DTSY450-1 (Direct connected) Class 0.5 3×57.7/100V 3×220/380V 3×230/400V 3×1.5(6)A Class1 DTSY450-2 (Transformer operated) Class1 3×220/380V 3×230/400V 3×5(30).3×10(40),3×20(80) Technical specification Meter constant: Model DTSY450-l 1.5(6)A: 1600imp/kW•h; Model DTSY450-ll 10(40)A: 400imp/kW•h; Basic error Load currentPower factorbasic error (%)Class 0.5Class 1.00.05lb1.0±1.0±1.50.1lb lmax1.0±0.5±1.00.1lb0.5L 0.8C±1.0±1.50.21lb lmax0.5L 0.8C±0.6±1.0Annual mean≤75%For 30 days, these days being spread in a natural manner over one year95%Occasionally on other days85%Installation and Connections Suggest installing the meter indoors and the base for fixing the meter shall be fixed on the solid and fore-resistance wall. The upper end of the meter has a hole of pothook bolt, it is fixing by M4 pothook bolt. There are two fixing hole on the bottom part of the meter for fixing on the connection board by bolts of M4×10 and M4×12.The base for fixing the meter shall be fixed on the solid and fire-resistance wall. The outline of the meter is shown in Figure 1. The meter shall be connected according to the connection diagram imprinted in the terminal Cover. Connection for power supply terminalsTransport and Storage The meter shall be handled carefully to avoid severe shock during transport, It should be transported and stored according to the requirements specified in the national standard GB/T15464-1995 "General Technical Requirements for Packaging of Instruments and Apparatus". The meter shall be stored on the shelves with its original package, the stacking height shall not more than five layers. Keep the storage place clean. The storage temperature shall be within 0 40 and the relative humidity is less than 85%. There's no injurant in the atmosphere which result in corrosion.Identification No. of the meter. The ID No. of the meter is the same as the number stated in the name plate. SIZE:

交货条款及包装

Packaging Detail: carton Delivery Detail: 15-30days
端口: Ningbo or Shanghai

付款条款

Letter of credit

Telegraphic transfer

Western Union

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称