阶段 |
三阶段 |
出生地 |
Guangdong China (Mainland) |
牌子的名字 |
JAZ |
模式的数量 |
DTSD1036A |
准确性的课 |
0.5\1.0 |
面 |
296*173*77mm |
1. GeneralModel DTSD1036 / DSSD1036 Poly phase multi-function Energy Meters,is designed to satisfy industrial demand with state of art technologies,adopting LSI,digital sampling technology and SMT production process. The product conforms to all technical requirements of multi-function meter specified in GB/T17215,GB/T178831999 and DL/T6451997 as well as IEC62052-11, IEC62053-21, IEC61036, IEC60687, IEC61268. 2. Main features u Measuring instantaneous voltage, current, power and frequency of the phases; u Record function of voltage-loss (phase failure), current-loss, voltage eligible rate, electric break and restore, programming, maximum demand clearing, broadcast time synchronization and so on; u Measuring import and export active energy (TOU); Measuring positive and negative reactive energy (TOU) ; even export and import reactive energy can be defined and recorded accordingly; u Measuring Maximum Demand of positive active/reactive, negative active/reactive (TOU); u Power supply quality monitor; to detect and record events of phase voltage lose, phase current lose, unqualified voltage sag, power outrage, programming parameterization (broadcast time calibration, reset etc.,) u Maximum programming 4 tariffs, 16 day tables, 4 season year tables and 12 holiday tables; u LCD display with 6 integers and 2 decimals; u Detection of LCD display segment, operating status, battery consume and memory alarm u For the program of important parameterization, controlled by password and internal hardware switch; u Automatic scroll display with quick scan function; maximum 36 scroll display items can be set freely as well as display sequence and interval time; u Built-in RTC clock, broadcast time synchronization via RS485 communication interface; u Going to sleep-mode while power outrage; during power failure it can be waken up by pressing Button or infrared HHU to transfer data from meter to HHU or PC with the support of backup battery; u Fast and Convenient replacement of backup battery without removing the upper cover; u Provided with 2 RS485 port (optional) and 1 optical port; it can communicate with PC or HHU via two RS485 ports and optical port in the meantime; u Baud rate: RS485 port 1: 1200bps960bpsRS486 port 2: 1200bps; u Expand functionalities (option); Load profile, frozen energy consumption data, detection of current even during power failure;3. Technical data 3.1 Operating Voltage: (3 elements) 3×220V/380V3×57.7/100V(2 elements) 3×100V; 3.2 Current: 0.5(2)A, 1.5(6)A; 3(6)A, 10(40)A, 15120A 3.3 Frequency 50/60 Hz 3.4 Accuracy Class Class 0.5S/1.0 (kWh); Class 2 (kvarh) 3.5 Power consumption≤2W/5VA (each phase) 3.6 Climatic condition Normal operating temperature 25+55 Limit operating temperature40+70 Relative humidity ≤85 3.7 Weight 2.4KG (approximately) 3.8 Profile dimension 296mm×173mm×77mm