Operating Method: Before to use the drencher, please rotate and take down the parts of barrel (No.1 and 2), disinfect the drencher (syringe) by liquid or boiling water (High-pressure steam sterilization is strictly prohibited), then assemble and put the fluid-suction hose on the water-sucking joint (No.14), let the hose joint with fluid-suction needle (No.23).Adjusting the adjusting nut to the required dose, put the fluid-suction needle into the liquid bottle, push and pull the small handle (No.19) to remove the air which is in the barrel and tube, then suck the liquid.After using the drencher, put the fluid-suction needle into the fresh water, repeated sucking the water to flushing the residual liquid until the barrel is cleared enough, then dry it. Remember to lubricate the O-ring piston (No.6) by the olive oil or cooking oil after you have used it for a long time.When to use it in injection way, just change the drenching tube (No.1) into the syringe head (No.26).If it can’t suck the liquid, please check the parts of No.3, No.4, No.5 and No.11, No.12, No.13 and make sure they are installed correctly. Ensure that the valve (No.5 and No.13) is clear enough, if there are some debris, please remove them and re-assemble the drencher. Also you can change the parts if they are damaged.It can adjust the elastic level according to the different use condition by the elastic adjustment nut (No.15).