阶段 |
单独一个阶段 |
出生地 |
Guangdong China (Mainland) |
牌子的名字 |
JAZ |
模式的数量 |
DDS1036F |
准确性的课 |
1.02.0 |
工作温度 |
-25----+55 |
面 |
150*106.5*61 mm |
1. General Model DDS1036F static single-phase energy meter is designed by using special large-scale integrated circuit (IC). With advantages of few components, simple construction, high reliability, low power consumption and long service life, it may be used in measuring single phase AC active energy with rated frequency of 50/60Hz. The meter conforms to all technical requirements specified in IEC 61036, IEC62052-11IEC62053-21 2. Features 2.1 Active energy measuring. 2.2long-term operation without calibration need 2.3 Reversed energy counted into total energy register. 2.4LCD display. 2.5 Excellent error linearity within 5%Ib Imax. 2.6 Long service life and high reliability due to adopting high quality components. 2.7 Life seal with ultra-sonic welding casing 3. TECHNICAL DATA 3.1 Nominal voltage 120V 220V 3.2 Basic current 10(40)A 10(50)A 15(60) A 20(80)A 30(100)A 3.3 Nominal frequency50/60Hz 3.4 Accuracy Class 1.0 2.0 3.5 Start current0.5%Ib 3.6 Power consumptionLess than 1W/10VA 3.7 Climatic conditions Normal operation temperature-25-----+55 Limit operation temperature-40-----+70 Relative humidityNo more than 85% 3.8 Weight0.50kg 3.9 Dimension150mm×106.5mm×61mm