出生地 |
Henan China (Mainland) |
牌子的名字 |
kaide |
模式的数量 |
KDLD |
1.Introduction: KDLDInsertion electromagnetic flow meter is manufactured with the modern technology of electromagnetic flow, the measuring principle of which is based on the electromagnetic induction law of Farady. It is mainly used to measure the volume flow of conducting liquid and slurry in closed pipeline, applicable to industries like chemical, power supply, metallurgical mine, oil, water supply and drainage, paper making, pharmaceutical, food, etc.. 2. Specifications: ItemSpecificationsCaliber(mm) DN150 DN2000 Pressure(MPa)1.6Accuracy±1.0%ApplicablemediumConductiveliquidandslurryMediumTemperature≤100°CMediumConductivity≥5μS/cmMediumVelocity≤15m/sAmbientTemperature:-25°C +60°C,Humidity:5% 90%LinerMaterial----ElectrodeMaterialSS316L,Ti,Ta,HB,HC,etc.ConnectionWelded, 2" ball valve,4" ball valve Sensor materiaSS304,SS316 SignalOutput4-20mA; PulseDisplayLCDdisplaywithbacklight, able to displaypositiveandnegativeinstantaneousandaccumulativeflowCommunicationRS485, Modbus,RS232,HART,Profibus-DPPowerSupplyAC85-265V,45-63Hz,power≤20W;DC11-40V;lithiumbattery(3.6V) ProtectionGradeIP65(convertor), IP67/68(sensor)Explosion-proofGrade Exdm2CT4,md2BT4Available FormCompact/Remote