出生地 |
Illinois United States |
牌子的名字 |
ACTIS |
模式的数量 |
BIR 500/225 |
BIR 800-450 is a Computed Tomography (CT) and Digital Radiography (DR) system capable of highspatial resolution, density discrimination, flaw detection and reverse engineering (RE). CT images can beobtained in either the Rotate Only (RO) mode, Asymmetric RO (ARO), or Continuous Rotate & Step(CRS) mode. The system can be configured with multiple sources and detectors for maximum flexibilityto cover a wide range of applications. A standard configuration for automotive casting applicationsconsists of the following items:• 450 kV x-ray system with Comet HP insert;• 1024 channel, solid-state detector array;• data acquisition system with 18 bit A/D converter;• tungsten x-ray beam optics including precision source exit and detector slice width collimators;• BIR Intel®Dual Xeon™ workstation, software, and flat panel color image displays;• six-axis machine tool grade precision manipulator with linear servo drives;• cabling, accessories, installation, training, and documentation;• one year on-site warranty with two PM visits as detailed in Appendix A.Varian CT systems are designed for x-ray inspection of automotive, aerospace, and industrial components over a wide range of density and materials including plastics, composites, light alloys, iron, and steel. The system produces cross sectional CT images and projection digital radiographs. In addition to density mapping, CT provides complete 3-D morphology of parts with highly accurate dimensioning capability.CT also provides superior flaw detection capability of extremely small cracks, porosity and voids that are normally not visible with film radiography inspection. The 450 kV source is capable of producing excellent quality CT images through solid cylinders of aluminum at 225 mm diameter or steel at 80 mm diameter. This is equivalent to detecting voids of less than 1 mm diameter. Radiographic images through 300 mm of aluminum or 100 mm of steel can be produced at 450 kV.The performance specifications of the standard BIR 800-450 system are as follows: 1. 450 kV X-Ray System -2. Detector System - BIR 250D solid state linear array3. Object Size & Weight - Varian Medical Systems, Security & Inspection ProductsJanuary 9, 2008encoders. The actual detector positions are used in datacollection and image reconstruction to insure artifact freeperformance.800 mm maximum clearance between tube pre-collimator and detector slice-width collimator;Asymmetric RO mode CT image maximum diameter 525 mm, 10 mm clearance to detector,full vertical travel;100 kg maximum object weight for full measurement accuracy performance;Object height is limited by the room or enclosure;Source & detector tower vertical travel is 1200 mm.4. CT Scan Modes -Centered Rotate Only (RO) Asymmetric RO (ARO)Continuous Rotation & Step (CRS) Over-Sampling 5. CT Spatial Resolution - RO 4X oversample, 1mm focus, 3.33 ma, 5 minute scan 3.0 lp/mm @ 10% modulation;Spatial resolution measured using ASTM Standard 1695-95 on image of 100 mm plastic disk. 6. Object Size & Weight -