Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer

杭州市, 中国
杭州市, 中国
公司
86-571-88228269
Jessie Shao
联系人姓名

基本信息

出生地 Zhejiang China (Mainland)
牌子的名字 CH
模式的数量 3500 Series
Atomic Absorption Spectrophotometer SP-3500 Seriesis a new generation of domestic high level products that it broke the technology bottleneck of D-lamp background correction. And also provided a reliable safeguard for elements quantitative analysis CharacterUnique full reflection optical systemD-lamp background correctionHigh resolution and exact peak seeking ability3 Atomic temperature rise modeUnique design automatic 8 lamps holder systemSteady flow full titanium burnerIntelligence control functionGeneral safety precautionsWindow2000/XP conciseness, professional, automatic, full operation SP Win-AAS softwareQA/QC functionFull information measurement Products TypeSP-3520AA (FLAME)SP-3530AA(Enhancement type)SP-3500GA(Graphite furnace power supply)SP-3530GA(Graphite furnace power supply)SP-3500AA SP-3520AA (FLAME) SP-3530AA(Enhancement type) SP-3500GA(Graphite furnace power supply) SP-3530GA(Graphite furnace power supply)Model SP-3520AA SP-3530AAMain Parameter Optical System Instrument Type Single Beam Reflection Achromatic Optics SystemMonochrometer: Achromatic C-TBandwidth(nm):0.1,0.2,0.7,1.4nm AdjustableWavelength Range(nm):190-900Wavelength Accuracy(nm):±0.20Wavelength Repeatability(nm):≤0.10Resolution better than 0.3nm(Mn279.5nm and 279.8nm peak valley≤30%)Spectrophotometric Properties Measurement: A.T.CPhotometric Range:0-125%,-0.1-3.00AStatic Baseline Drift(Cu):±0.003A/30minDynamic Baseline Drift(Cu):±0.004A/30minBackground Correction: D-lamp background correction,Self-absorbance background correction >50times correction ability(1Abs)Atomization System: Flame + graphite furnaceFlame Characteristic Concentration:(Cu)≤0.03ug/mL/1%Detection limit:(Cu)≤0.006ug/mLPrecision:RSD≤1%Burner:titaniumNebulizer:hight-efficient glass nebulizerSpray chamber:anticorrosion materialSafety measures:Flame fuel gas, power assisted gas abnormal pressure protectionGraphite FurnaceCharacteristic quantity Characteristic value: Cd≤0.5×10-12gDetection Limit Characteristic value: Cd≤1.0×10-12gPrecision Precision: Cd≤3%Test Manner :Flame, Graphite Furnace, hydride-AA, flame emissionData ProcessConcentration:Standard curve, standard addition, interpolationTimes of repetitive Measurement:1-30times,Average value of A&CQA/QC:relative coefficient,Abs. concentration SD,RSD,Analysis data electronic document export is feasible.data output:Test data could be saved as original record form through Pro-softwarereport print:parameters, data result, graphdata interface:Standard RS-232 interfaceInstrument function Instrument setup D-lamp background correction auto-adjust optics beam deviceAutomatic wavelength scan, peak seeking band width adjustAutomatic ignite adjust negative high voltagelamp current, balance two beams, flameout protection

交货条款及包装

端口: Shanghai

付款条款

Letter of credit

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称