A8-24 type automatic water sampler

A8-24 type automatic water sampler

原价: 1 488 USD
北景乡, 中国
生产能力:
10000 纸板箱 / 年
北景乡, 中国
公司
86-010-86662682
Yaqi Zhao
联系人姓名

基本信息

模式的数量 A8-24
出生地 Beijing China (Mainland)
牌子的名字 automatic water sampler
A8-24 type automatic water sampler A8-24L type (sub-mining fixed freezer refrigeration) automatic watertreatment for total control, pollution sources and water quality monitoring survey of a dedicated environmental monitoring instruments. It uses advanced way peristaltic pump water from the single-chip control. Users can enter the sampling interval, sample volume and sampling sub-sample means. It can automatically complete the corresponding online work. Flow Sensor Adapter, you can achieve the effluent measured by the ratio of sample flow of the double work. Also with other online networking monitoring equipment for accident alarm remote control sampling and sampling. Widely used in industrial and mining enterprises sewage monitoring, scientific research institutions of higher learning environment, as well as the implementation of environmental protection departments to carry out the total pollution control and monitoring the work of investigation, one of the necessary equipment. A main performance indicators: 1. Sampling Control: u-time-control sampling: l the same time interval (1 min -9999-minute set of arbitrary, one-minute increments). l different time intervals (1 min -9999-minute set of arbitrary, one-minute increments). u flowmeter control sample: l-specific control sample flowmeter. l output sampling control pulse flowmeter (1-9999 arbitrary pulse, a pulse increment. lose The pulse should be 5V-15V positive pulse). 2. Water points installed by: u A N bottled water samples (mixed samples taken): 1 u like a water bottle packaging N (samples taken in parallel): 1 3. Sample volume: 50 - 1000 ml arbitrary, incremental 1 ml. 4. Sampling Repeatability: ± 10ml. 5. Peristaltic pump suction vertical-way (head): 7.2 meters, with automatic flushing sampling tube function. 6. Water containers: 24 1000ml polyethylene storage bottle. 7. Water storage temperature: 0 - 8 adjustable. 8. All the Chinese menu, man-machine dialogue, the need for human intervention when the Chinese have prompted al. 9. Software locks can be set up to protect the process equipment will not be modified. 10. 10 samples can be stored procedures, after matching the flow meter data, including date, time, instantaneous flow rate and accumulated flow. Sampler can store 256 sets of data, the use of cycle updates. The use of this feature, you can calculate the time to disable devices. 11. In accordance with the ratio of sample flow, each time a sample into the instrument within, you can view or print. Users based on these time and draw the flow of sewage discharge plans. 12. Networking functions: the results can be sampled, the flow of data through a wired or wireless transmission to the central control computer, the computer-controlled through the remote control sampling. Also with other online network monitoring equipment, sample accident report to the police. 13. Samplers connected with the flowmeter since, if man-made flow meter plug pulled out, according to the largest set of instantaneous traffic flow records. 14. Working ambient temperature: -5 to +50 . 15. Power Supply: AC220V ± 10%, power 80W. 16. Dimensions: 550mm'500mm'835mm (length 'width' height). 17. Weight: 28Kg. Second, use the keyboard 1. Function keys u POWER ON: power supply connected to equipment Power-u: to cut off power supply apparatus u manual /: manual sampling (second function: to enter the decimal point). u stop / transfer bottles: from the current menu and return to previous menu level. (Second function: the distribution of arm movement to the next reservoir bottle) u pump is to switch /: pump pumping. (Second function: used to select the menu that appears, flashing that is selected) u pump inversion /: drainage pumps. (Second function: used to select the menu that appears, flashing that is selected) u Automatic: Automatic Sampling u: "Enter" key to confirm the parameters entered and select items. Each input parameter or a selection Optional finish that is key here. 2. The number keys 0 - 9: Enter the required values for. Third, the use of samplers Note: 1. AC220V power equipment used to take a good ground to ensure safety. 2. Reserve has lettering on the bottle basket, boot after reset distribution arm of the reservoir bottle into the first bottle, anti-clockwise followed by the second, third ... .... 3. Place sample bottle, the bottle must be adopted by in the end, so as not to encounter dispenser bottle with the sample not work correctly. 4. Pump tube should be regularly checked, if the damage should be immediately replaced. Replacement of pipes and pump when the pump shell to stay between 2-3 mm gap, replace the pump tube, the press is to pump or pump reverse button, so that a pump will rotate until the pump is operating normally, no stuck phenomenon pump tube is installed. 5. Unusual equipment, please cut off the power immediately and notify the factory maintenance, will not be permitted to demolition. 6. Responsible for water samples at different sampling bottles prior to the distribution of arms to adjust the factory, and not man-made hand-twisting.

交货条款及包装

Packaging Detail: wooden case Delivery Detail: as soon as possible
端口: tianjin

付款条款

Letter of credit

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称