363kV Dead-tank CB,363kV CB

363kV Dead-tank CB,363kV CB

中国
生产能力:
240 设置 / 年
中国
公司
86-029-84244864
Xiaoying Liu
联系人姓名

基本信息

出生地 Shaanxi China (Mainland)
牌子的名字 XD
模式的数量 363kV Dead-tank CB
1, Superior interrupting capability These breakers can cope with all known switching phenomena (including line charging current, small inductive current etc). The severe rate of rise of the recovery voltage by a short-line fault and the high recovery voltage peak by out-of phase interruption are both cleaned by the efficiently designed interrupter. In magnetizing current switching, the over voltage is less than twice the applied voltage. No restrike or reignition occurs on charging current switching. They also have an advantage of long electrical endurance. 2, Reliable insulating and current-carrying capability Because of SF6 gas as the insulating medium in produces and even distribution of electrical field, the breaker have a reliable insulating capability. SF6 gas protects the contacts from oxidization and other chemical reactions as SF6 gas is stable and inert when used with most materials. Item 363kV CB single break 363kV CB double breaks 550kV CB double break 550kV CB single break Unit Installation Indoor or outdoor Ambient air temperature -30 40 °C Max. daily difference in temperature 25 °C Altitude ≤1000 (3000 for dead tank CB) m Relative humidity per month ≤90 % Earthquake intensity Horizontal acceleration 0.2 (0.4) g Vertical acceleration 0.1 (0.2 ) g Degree of Contamination III Max. Ice coating thinkness 10 mm Max. wind 35 m/s Rated voltage 363 550 kV Rated frequency 50 (60) 50 Hz Rated nominal current 3150 4000 4000 A Rated breaking current 50 50,63 50 kA Making current 125 125,160 125 kA Rated short-time withstand current 3s 50 50,63 50 kA Rated peak withstand current 125 125,160 125 kA Short-line fault breaking current leX90%, leX 75% kA Out-of-phase breaking current leX25%, kA Creepage distance 2.5, 3.1 cm/kv Rated 1 min power frequency withstand voltage Across breaks 720 657 890 998 kV To earth 510 510 740 680 kV Rated lightning impulse withstand voltage (peak) Across breaks 1175+295 1175+295 1675+450 1675+450 kV To earth 1175 1175 1675 1675 kV Rated switching impulse withstand voltage Across breaks 950+295 950+295 1175+450 1175+450 kV To earth 950 950 1175 1175 kV Rated 5 min. power frequency withstand voltage under zero-gage pressure Across breaks 1.3×363/√3 1.3×550/√3 kA To earth 1.3×363/√3 1.3×550/√3 kA Rated operating sequence O-0.3s-CO-180s-CO Open time ≤30 ≤20 ≤22 ms Breaking time ≤50 ≤40 ms Closing time ≤ 100 ms Close-open time 35-60 ms Operating asynchronism Between poles Open ≤3 ms Close ≤4 ms Across breaks Open ≤2 ms Close ≤2 ms Mechnical endurance ≥ 5000 Times Number of breaks per pole 1 2 1 Mechanism Pneumatic or hydraulic

交货条款及包装

Packaging Detail: wood package Delivery Detail: 5months aftersigningcontract
端口: tianjin or shanghai
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称