35KV Heat Shrinkable Joint

35KV Heat Shrinkable Joint

原价: 19,90 USD
肃州镇, 中国
生产能力:
10000 设置 / Day
肃州镇, 中国
初学者
0086-512-66651289
Feng shen
联系人姓名

基本信息

出生地 Jiangsu China (Mainland)
牌子的名字 CSHN
模式的数量 JSY35
Product Introduction: 35KV heat shrinkable joints are designed for 1 and 3-core XLPE power cables. The whole set contains heat shrinkable outer and inner insulation tubes,stress control tubes, sealing tubes,protective tubes,self adhesive tape and voil filler.Its unique patented water-proof design ensures the higher security of cable accessories. Its high permittivity material endows it unique stress control system. And with compact design and few components, this product is easy to install, minimal waste for disposal. Fast, consistent installation means lower installing costs. Installation environment: use of torch adds flexibility to cable preparation in any climate. It also has high reliability. Heat-activated seals ensure maximum protection against moisture ingress. Lightweight construction requires no additional support. UV resistant, non-tracking outer tube for long life, even under adverse conditions. It also has excellent mechanical robustness. Characteristics: 1.Operating Temperature:-40 degree - 110 degree; 2.Shrink Temperature:90 degree; 3.Waterproof, RoHS compliant. Technical Data: PROPERTYTEST CONDITION AND TEQUIREMENTRESULTSAC withstand for 1 min.(dry withstand, for indoor termination)No breakdown and flashover shall occur at 105kV, 1minNo breakdown and flashover occurred on the combi.sample at 105kV, 1minPartial discharge39kV, ≤10PC39kV, ≤10PCLoad cycleHeating for 5h, cooling for 3h. Conductor's temperature is 95, 3 cyclesConductor's temperature is 95. Results refer to the following testImpulse voltage withstand 1.2/50us±10times10 positiVe and 10 negative impulses at 250kV, flashover 1 time is allowed but not including total testing timesNo breakdown of the combi.sample occurred at 250kVDC voltage withstand negative 15 min.No breakdown and flashover shall occur at 156kVNo breakdown and flashover occurred on the combi.sample at 156kV, 15minAC voltage withstand, 4hNo breakdown and flashover shall occur at 104kV, 4hNo breakdown and flashover occurred on the combi.sample at 104kV, 4hOil-seal up testHeating for 24h, cooling for 24h. Conductor's temperature is 65, oil pressure: 100MPANo leaking, no seeping(Only for Paper insulated cables)

交货条款及包装

Packaging Detail: one set per polybag Delivery Detail: 10 workdays
端口: Shanghai

付款条款

Documents Against Payment

Letter of credit

Telegraphic transfer

MoneyGram

Western Union

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称