"WATER SABLE" TPO Waterproof Sheet

"WATER SABLE" TPO Waterproof Sheet

zhifei zhou
联系人姓名

基本信息

WATER SABLE S-501 TPO Waterproof Sheet A. Introduction Thermoplastic Polyolefine Waterproof Sheet Utilizes High-tech polymer technology and unique formula and have both the advantages of EPDM sheet in weather resistance and low-temperature lexibility and PVC sheet in easy-welding. B. Characteristics Have long-term weather resistance without any plastic-enforced additive and apply High-tech polymer technology. Good performance of high crack resistance, elogation to break and resistance to roof penetration. The joint is better than the sheet through welding, with smooth, continuous and even surface. The lighter colour surface can lower the roof temperature and formcool roof. It doesnt contain chlorinated polymer and chlorine, so it is environment-friendly and can ensure the construction safety. C. Application It can be widely used in the waterproof, leaking-prevent and dampproof project of concrete roof, steel structure roof, underground spaces, subway, irrigation works, tunnel and landfill. D. Main technology data N Type TPO sheet NoItemUnitIndex1Tensile strengthMpa172Elongation to break%6003Cold blending≤-35No crack4Impermeability0.4Mpa,72hNo leaking5Root resistanceNo penetration6Resistance to tearingN/mm25 L Type TPO sheet( with the fabric) NoItemUnitIndex1Tensile strengthN/cm602Elongation to break%3003Cold blending≤-35No crack4Impermeability0.4Mpa,72hNo leaking5Root resistanceNo penetration6Resistance to tearingN/mm257Heating up variabilityLognitudinal (%) ≤ 1.5Transverse (%) ≤ 1.58Fire Resistance B2 E. Specifications Thickness (mm) 1.0, 1.2, 1.5, 2.0, as required Length (m) 15, 20, 25, as requried Width (m) 1.90, 3.10, 3.70, as requried F. Construction Instruction Base Treatment The base should be smooth without any outstanding avoid of damage to the sheets. The base should be cleaned of impurity before construction. The requirement of the mechanically fastening surface: the profiled steel sheet should be more than 0.7mm thick and the height of the upper and lower is more than 50mm and tied firmely. fasten the insulation board to the profiled steel sheet with screws. Construction Technics The overlapping of the TPO sheet should use the hot-air welding method. First locate and form datum line. Then lay the sheet vertical to the corrugation direction. Lay the sheet on the base. Ensure the sheet is flat and in a line. The width of the joint is 6 cm. Use the auto welding tool or handle welding tool to weld and do some proper cuting and install the fastners in the designed location. Details The TPO sheet should be fastened by the matched fasteners in the endings and coat sealant to seal. The sheet is cut into different shapes to add in the place of outside and inside corners and then welded. Cautions in construction The workers should be trained before construction. It is not allowed to wear the shoes with nails in the construction sites. Examine the welding quality avoid of any defects in the welding, and smoking is forbiddened in the construction site. G. Storage and transportation The product shoud be stored in the well-ventilated warehouses and far away from the acid, alkali, oil, and organic solvent.

交货条款及包装

賣家沒有明確指定交貨條件。 有關更多信息,請聯繫賣家。

付款条款

Telegraphic transfer

Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    Рынок B2B
    取消
      查看更多
        地區搜索
        全球
        Категории
          产品名称