出生地 |
Japan |
牌子的名字 |
omron |
模式的数量 |
OMRON E2EM-X15X1 2M Proximity Swi... |
麦克斯。 目前的 |
... |
麦克斯。 电压 |
... |
OMRON E2EM-X15X1 2M Proximity Switch specificationRATING AND PORFORMANCEShieldShieldedCylinder type sensing head sizeM30Sensing methodInductive typeSensing distance15 mm -10% to +10%Setting distance0 to 12 mmDifferential distance10% Max. of sensing distanceSensing objectFerrous metal (Sensitivity lowers with non-ferrous metals.)Standard sensing objectIron 30*30*1mmResponse frequencyDC: 0.25 kHz (average)Power supply voltage12 to 24 VDC (ripple(p-p) :10% Max.)Operating voltage range10 to 30 VDCLeakage current0.8 mA Max.Control output (Output type)DC 2-wire models with no polarityControl output (Switching capacity)3 to 100 mAControl output (Residual voltage)(DC) 5 V Max. (under load current with cable length of 2m)IndicatorOperation indicator(red), Operation setting indicator(green)Operation modeNOProtective circuitSurge suppressor Output short-cut protectionStandard or Different frequencyStandardAmbient temperatureOperating: -25 to 70 CEL Storage: -40 to 85 CEL (with no icing or condensation)Ambient humidityOperating: 35 to 95 %RH Storage: 35 to 95 %RH (with no condensation)Temperature influence+-15% Max. of sensing distance in temperature range of -25 to +70CEL (As the basis for sensing distance of 23CEL)Voltage influence+-1% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage)Insulation resistance50 M OHM Min. at 500VDC between charged parts and the caseDielectric strength1000 VAC 50/60 Hz for 1 minute between charged parts and the caseVibration resistance10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directionsShock resistance1000m/s2 for 10 times each in X, Y, and Z directionsDegree of protectionIEC60529: IP67 Company standard: Oil-proofApplicable standard (EC Directive (Low Voltage Directive))EN60947-1 EN60947-5-2Applicable standard (EC Directive (EMC Directive))EMI: EN60947-5-2 Emission Enclosure: CISPR11 Group 1 classA EMS: EN60947-5-2 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Burst: IEC61000-4-4 CE marking: EquippedApplicable standard (CCC mark)Not equippedConnection methodPre-wired models (Cable length: 2 m)Weight (Packed state)approx. 180 gMaterial (case)Brass nickel platingMaterial (sensing surface)PBTMaterial (clamping nuts)Brass nickel platingMaterial (toothed washer)Iron zinc plating