出生地 |
Guangdong China (Mainland) |
牌子的名字 |
PLIZI |
模式的数量 |
CP series |
Power Supply Online UPS SyestemOnline UPS System have smart mangagement.LCD+LED display Online UPSCold Start Online UPS1. Superior ability to adapt electric networks 220V±25% of wide input voltage range makes UPS work normally in poor power environment, it reduces the battery discharging opportunity and extends battery life. 2. Super load compatibility Strong carrying capacity, load compatibility, can be applied to different types of load, meet various application needs. 3.Zero transfer time Built-in static bypass electronic switch, if UPS is under protection or breakdown, the power supply will be switched to bypass without interruption. It especially suits equipments that have strict time requirements of power-fail. 4. Perfect battery management Offer the most reasonable charging current according to battery parameter curve, set the best charging current according to battery capacity, improve battery efficiency, extend battery lifespan. 5. Intelligent monitoring function Communicate with computer through RS232 interface and UPS intelligent monitoring software, display UPS working parameters on screen. UPS can also achieve network monitor through the installation of SNMP card, and can be observed and managed UPS working parameters remotely through the network. 6. Series connection hot backup and parallel connection redundancy can be achieved. ModelCP801CP802CP803CP804CP806CP808CP810CP815CP820Capacity1KVA2KVA3KVA4KVA6KVA8KVA10KVA15KVA20KVAOperating principlePure sine wave dual conversion on-lineAC inputPhasesingle-phase L+N+GVoltage220V±25%Frequency50HZ±10%DCRated DC voltage48Vdc192Vdcfloating voltage54.5Vdc218VdcCut-off voltage42Vdc168VdcCharging timecharge to 90% in 8 hoursAC outputPhasesingle-phase L,N+GVoltage220Vac±2%( stable load), 220Vac±5%(fluctuant load))Frequency50Hz±0.5%( On battery)Power factor0.8Wave-formSine waveTotal voltage harmonics distortionlinear load <3%,non-linear load <5%Output voltage transient characteristic±5%( Load abrupt change From 0 to 100%)Transient response time<20msCrest factor3:1Overload protection>125%,1min:>150%,200msSystem specFull load efficiency≥90%Transfer time0msProtectionOverload, over charge and over discharge: out the range of voltage and frequency, over current, short circiut, over temperature ect.DisplayLCD and LED indicatorCommunicationRs232 interace and SNMP card(optional)Environment temperature-5 40°CRelative ambient humidity20 95% (Non-condensing)Altitude<1500m: 1% rated capacity decrease against rised 100mSafety rateIP21Cooling methodforced air-cooling with temperature controlNoise (dB)<55dB<60dBDimension (W*D*H)mm200×480×490210×612×540240×540×680330×640×885550×450×1080/380×681×935Weight (Kg)396674656785110125200