出生地 |
China (Mainland) |
牌子的名字 |
Meanwell |
模式的数量 |
NET-75B |
输入电压 |
85~264VAC |
产出电压 |
DC 5V |
产出种类型 |
三倍 |
MODEL NET-75BOUTPUT NUMBER CH1 CH2 CH3 OUTPUTDCVOLTAGE 5V 12V -12V RATEDCURRENT 5A 2.8A 0.5A CURRENTRANGE 0.6 7A 0.2 3.5A 0.1 0.7A RATEDPOWER 64.6W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p VOLTAGEADJ.RANGE CH1:4.75 5.5V VOLTAGE TOLERANCE Note.3 ±2.0% ±6.0% ±5.0% LINEREGULATION Note4 ±0.5% ±1.0% ±1.0% LOADREGULATION Note5 ±1.5% ±3.0% ±1.0% SETUP.RISEHOLD.TIME 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load HOLD TIME(TYP.) 50ms/230VAC 10ms/115VAC at full load INPUTVOLTAGERANGE Note.6 85 264VAC 120 370VDC FREQUENCYRANGE 47 63HZ EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) 1.5A/115VAC 0.9A/230VAC INRUSH CURRENT (Typ.) COLD START 45A LEAKAGECURRENT <2mA/240VAC PROTECTIONOVERLOAD 110 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE CH1: 5.75 6.75V Protection type : Shut down o/p voltage, re-power on to recover ENVIRONMENTWORKING TEMP -20 +60 (refer to output load derating curve) WORKINGHUMIDITY 20 90% RH non-condensing STORAGE TEMP HUMIDITY -40 +85 10 95%RH TEMPCOEFFICIENT ±0.03%(0 45) VIBRATION 10 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY&EMCSAFETY STANDARDS UL60950-1, CB(IEC60950-1) approved WITHSTAND VOLTAGE 1/P-0/P:3KVAC 1/P-FG:1.5KVAC 0/P-FG:0.5KVAC ISOLATIONRESISTANCE 1/P-0/P,1/P-FG,0/P-FG:100M Ohms/500VDC EMI CONDUCTICN& RADIATION Compliance to EN55022(CISPR22)classB HARMONICCURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A QTHERSMTBF 361.6Khrs min. MIL-HDBK-217F (25 ) DIMENSION 159*97*38mm (L*W*H) PACKING 0.52Kg; 30pcs/16.6Kg/0.97CUFTNOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.6. Each output can work within current range. But total output power can't exceed rated output power.7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.