В металлическом корпусе низкого напряжения Распределительное устройство

В металлическом корпусе низкого напряжения Распределительное устройство

ориг. цена: 10 000 USD
Шанхай, Китай
Объем производства:
500 Набор / Месяц
Шанхай, Китай
Начальный
86-21-33521117
Brian Chueng
Контактное лицо

Основные данные

Место происхождения Shanghai China (Mainland)
Бренд CHFE
Номер Модели GGD
Standards GB7251.1 Low-voltage switchgear assemblies IEC60439 Low-voltage switchgear and controlgear assemblies Service condition 1. Ambient temperature: -5'C +40'C. Average temperature in 24 hours <= 35'C. 2. Altitude: <=2000m. 3. Air humidity at 40'C <=50%. Higher humidity at lower temperature is permitted. Occasional condensation due to temperature variation should be considered. 4. No excessive vibration. 5. No corrosion to electric elements. Special condition subject to users. Features and Benefits 1.The optimized footprint uses smaller section sizes when possible. Sections are provided in 22", 30" or 38" widths.2.Breaker compartment doors have no ventilation openings, thus protecting operators from hot ionized gases vented by the breaker during circuit interruption.3.A superior bus system offers different levels of protection. Insulated and isolated bus makes maintenance procedures touch friendly to reduce the risk of arc flash.4.True closed-door drawout construction is standard with all GGD equipment. The breaker compartment doors remain stationary and closed while the breaker is racked out from the connect position, through test, to the disconnect position. Doors are secured with rugged 1/4-turn latches.5.An easy-to-read metal instrument panel above each circuit breaker holds a variety of control circuit devices, including the RELT switch.6.Each circuit breaker is located in a completely enclosed ventilated compartment with grounded steel barriers to minimize the possibility of fault communication between compartments.7.Optional safety shutters protect operators from accidental contact with live conductors when the breaker is withdrawn.8.Easy access to equipment compartments simplifies maintenance of the breaker cubicle and control circuit elements as well as inspection of the bolted bus connections.9.The conduit entrance area meets NEC requirements. Extended depth frame options are available in 7" and 14“ sizes for applications requiring additional cable space. The section width also can be increased for additional cable space.10.A rail-mounted hoist on top of the switchgear provides the means for installing and removing breakers from the equipment. This is a standard feature on NEMA 3R outdoor walk-in construction and optional on indoor construction.11.Control wires run between compartments in steel riser channels. Customer terminal blocks are located in metal-enclosed wire troughs in the rear cable area. Intercubicle wiring is run in a wireway on top of the switchgear, where interconnection terminal blocks are located.12.All circuit breakers are equipped with rollers and a guidebar to provide easy and accurate drawout operation.13.An optional remote racking device reduces the risk of the arc flash hazard by allowing the operator or electrician to move the breaker anywhere between the DISCONNECT and CONNECT positions from outside the arc flash boundary.14.Optional infrared (IR) scanning windows can be installed in the switchgear rear covers to facilitate the use of IR cameras for thermally scanning cable terminations.15.GGD switchgear can be expanded easily to handle increased loading and system changes. Specify a requirement for a fully equipped future breaker to obtain a cubicle that has been set up for additional breaker installation, or add vertical sections without modifications or the use of transition sections.16.An array of safety interlock and padlocking features are available to accommodate any type of lockout-tagout procedure a customer may have.17.Optional Power Management: With the proper devices, facility power can be tracked and controlled.GGD Metal-enclosed Low Voltage SwitchgearModelRated voltage (V)Rated current (A)Rated short-circuit breaking current (kA)Rated short time withstand current (1s) (kA)Rated peak withstand current (kA)GGD-1000-15380A1000151530B600(630)C400GGD-1600-30A1500(1600)303063B1000C600GGD-3150-50A31505050105B2500C2000

Условия поставки и упаковка

Packaging Detail: Wooden case Delivery Detail: 25 days
Порт: Shanghai

Условия оплаты

Аккредитив

Электронный перевод

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций