указатель уровня воды

указатель уровня воды

Цанчжоу, Китай
Объем производства:
1000 Тонна / Месяц
Цанчжоу, Китай
Начальный
86-317-8310777
Ada shi
Контактное лицо

Основные данные

Место происхождения Hebei China (Mainland)
Бренд Dachang
Номер Модели DC100-300mm
Application The spirit level is mainly used for checking flatness of guide ways of various machines and equipments.and horizontality or verticality of installation of equipment. A. Type Graduation 0.02mm/m Unit:mm B. ration The reading can only betaken as soon as the air bubble is completely fixed. The value indicated on the level is the slope of the basic length with one meter long. If it is necessary.to measure the real slope value of alength L,it may be calculated by the following equation: Real slope value =Scale X LXReading value For example,scale value=0.02mm/m.L=200mm.reading value (bubble movement)=2 divisions,then: Real slope value=0.02/1000X200X2=0.008mm. C. Adjustment Place the instrument on asteady and smooth even board,after the bubble fixed,the reading should be [a], then rotate level to 180 °, place it again on the original position and take the second reading [b] The Zeroerror of the level is 1/2(a-b). Then loosen the fastening screw on one side of the spirit hex wrench of 8mm into the eccentric adjuster and start the zero-setting by turning the adjustrer.At this time,if the instrument is found to incline to the rear,and vice versa. For over 5 degrees, or the deviation of the bubble exceeds half a graduation,it will be necessary to make readjustment by turning the two adjusters on both sides of the level untl the bubble does not move to and frowith the tilting of the indtrument:Lastly,it is also necessary to check whether the zero point deviates or not .If it nolonger deviates,then lock the fastening screw,thus completing the cycle of the zero-setting . Before using,clean the working surface of the level with gasoline and wipe it with absorbent cotton. .Temperature changes would cause measuring error,therefore it should be keptaway from heat source and airdrafts during measurement. . Reading should be takenonly after the bubble has come stable about 15 seconds after the level has been located on the test surface. Attention must be paid to the zerq adjustment and the parallelism of the working surface of the level in order to avoid the distortion in leveling .inspection and adjustment are neceasuring.

Условия поставки и упаковка

Packaging Detail: Wooden box Delivery Detail: 7-30days after you order
Порт: TIANJIN

Условия оплаты

Аккредитив

Электронный перевод

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций