Место происхождения |
Shaanxi China (Mainland) |
Бренд |
XATH |
Номер Модели |
SFZ9 |
Использование |
Мощность |
Количество фаз |
Три |
Структура витков |
Тороидальная |
Количество витков |
Автотрансформатор |
Oil Immerseddistribution Transformers with 110kVTechnical Characteristics: Low loss: The no-load loss reduced by about 40%, and the load loss reduced by 15%, compares to the actual National Standards GB6451-1999Low noise: The noise level achieved below 60dB, dropped by nearly 20dB compares to the National Standards. We can also manufacture transformers (below 55dB) to meet customers requirementsLow partial discharge: The full procedure of 110kV products is completed in a depurated workshop, and the metal components, insulation components of the active part are completely rounded end. The partial discharge is controlled below 100pcStrong short-circuit withstand abilityGood Aesthetic: Corrugated tank, shot blast cleaning, electrostatic powder spraying, wide slice radiator and never-fadingNo leakage: All the sealing is fixed, the rims use two sealing and all the sealing is imported. Seriously promise to be no leakageStructure and Technical Features: WindingsHV winding adopts interleaved-continuous or inside continuous model, which improves the winding vertical capacitance distribution under the impulse voltage. Windings are oil-cycle structure so that they can reduce winding temperature rise. The products life is 30 years. The inside of winding has hard supporting and swallow-tail cushion, insulation of the top and the bottom ends are platform pressing plates, makes high mechanical strength and resistance to the sudden short circuit ability. Winding internal insulation parts and active parts of insulation are rounded to reduce partial discharge Active partThe active part assembled whole and dried under invariable pressure to ensure symmetrically shrink of windings with less rebound, so effectively improve electrical strength and the short circuit withstand ability. CoreThe core is made of high quality cold-rolled silicon-steel sheet, without holes, frame structure; the D type yoke structure offers the large area platform. Step-lapping and laminated, cut by step-lap core lamination line from GEORG Co. of Germany in order to guarantee core burr smaller than 20¦Ìm, reduce no-load loss, no-load current and noise level TankTanks structures are bell type and barrel type. The plates are curved to corrugated wall. All the sealing is fixed. Metal parts are round horn and go hair. Welding seam and sealed place pass three leakage testing (fluorescence, positive pressure, and negative pressure). The paint is according to the electrical appliances antirust requirements Technical Data Table of Forced Air Cooling Three-phase Two -windingOff-circuit Tap changing Power Transformers with Low-loss and Low-noisefor SF10 with 110kV TypeRated Capacity (kVA)Rated Voltage(kV)ConnectionSymbolNo-loadLoss(kW)LoadLoss(kW)No-loadCurrent (%)Short-circuit Impedance (%) SF10-6300/1106300H.V.110±2×2.5%121±2×2.5%L.V.6.36.610.511YNd11734.90.6410.5SF10-8000/11080008.442.50.6SF10-10000/110100009.850.20.57SF10-12500/1101250011.659.50.53SF10-16000/110160001473.10.5SF10-20000/1102000015.988.40.46SF10-25000/1102500019.6104.60.44SF10-31500/1103150023.4125.80.4SF10-40000/1104000027.7147.90.37SF10-50000/1105000032.9178.50.33SF10-63000/1106300039.12210.3SF10-75000/1107500043.22650.28SF10-80000/1108000049.63180.25SF10-90000/11090000573810.23SF10-100000/11010000065.54570.21SF10-120000/110120000755480.20SF10-150000/110150000866300.18SF10-180000/110180000987200.16