Температура и предохранительный клапан

Температура и предохранительный клапан

Ханчжоу, Китай
Объем производства:
1000000 Штука / Год
Ханчжоу, Китай
Компания
86-571-63800768
Susie Su
Контактное лицо

Основные данные

T&P Valve 1, Commodity name: Temperature and Pressure Relief Valve 2, Use:T&P Valve for solar water heater, electric heater and so on 3, T&P relief Valve Function: The T&P valve is designed to relieve the increase in pressure which develops during the normal heating cycle. This is caused by the water expanding during the heating cycle.The T/P valve then will relieve the increase in pressure by releasing drips of hot water to the drain line. It is recommended that an expansion control valve be fitted to the cold water supply line as it will relieve cold water(not hot water),during the heating cycle expansion,thereby saving energy and increasing the life of the T&P relief valve.Local regulations may make it mandatory to install an expansion control valve in the cold water supply line. Should the electrical temperature cut-out devices cease to operate correctly,the water will overheat and the temperature probe will then be activated to open the P/T valve,discharging hot water. 4, T/P relief valve for solar water heater Inlet pressure control: High pressure may cause excessive discharge and possible premature failure of the operating relief valve.The maximum water pressure usually occurs during the night, at the time of lowest water usage. In any mains pressure water heater installation,if the inlet water pressure exceeds 80% of the nominal set pressure of the operation relief valve,a pressure limiting valve must be fitted to the cold inlet.(If a cold water expansion control valve is fitted it will have a lower set pressure than the T/P relief valve and thus be classed as the "operating"relief valve.) 5,T&P Valve Installation: T/P Valves should be installed by a licensed plumber. If the temperature probe protruding from inside the inlet thread is damaged or bent,do not install,and obtain a replacement valve. Clean out all deposits from the threaded boss on the heater before fitting a replacement valve,otherwise the new valve risks contamination and premature failure.Apply PTFE thread tape to the male taper thread,making sure that the tape does not hang over the outerend of the thread,as this can lead to premature valve failure.Screw the valve into the heater socket.Do not use a wrench on the valve body.Use teh hexagonal spanner flats provided.No valves,taps,or other isolating devices are to be fitted between the P&T relief valve and the water heater. Install a drain line of the same nominal size as the valve,in accordance withAS3500.4.(The drain line must have a continuous fall.)

Условия поставки и упаковка

Packaging Detail: cartons Delivery Detail: 7days
Порт: China port

Условия оплаты

Документы за наличный расчёт

Аккредитив

Электронный перевод

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций