солнечный подогреватель термостатический смеситель

солнечный подогреватель термостатический смеситель

ориг. цена: 17,00 USD
Шэньян, Китай
Объем производства:
5000 Штука / Месяц
Шэньян, Китай
Компания
86-24-22510528
Bob Liu
Контактное лицо

Основные данные

Model: BXHS-15G-F 1. Technical Data a.Working pressure:0.03-1Mpa b.Ideal working pressure:0.1-0.5Mpa c.Maximum working temperature:≤99 Celsius degree d.Hot water inlet temperature range:50-99Celsius degree e.Cold water inlet temperature range:5-29Celsius degree f.Outlet Temperature range:35-45Celsius degree g.Adjustment Accuracy:+/-2Celsius degree h.Flow rate on 1 bar pressure drop:0.7Cb.m./H (Same as 11.67L/Min)i.Elbow outlet portFlow rate for pressure:Pressure(psi or kPa)1 psi5 psi(34kPa)10 psi(69kPa)15 psi(103kPa)20 psi(138kPa)30 psi(207kPa)Flow Rate(liters per minute)4.5912.515.117.628.2GPM0.982.02.73.33.96.2 2. Materials of Construction a.Valve body:Brass with Ni-Plated b.Shutter:PPO c.Spring:Stainless steel d.O-ring:EPDM e.Port:Inlets-M,Outlet-M 3.Features:a.Fail-safe on Hot or Cold Supply Failure b.Delivers Stable Mixed Water Temperature c.Extended Mix Temperature Range:35-45C d.Idea for Domestic Water Application 4. What is the thermostatic mixing valve? A Thermostatic Mixing Valve is a valve that blends hot water (stored at temperatures high enough to kill bacteria) with cold water to ensure constant, safe outlet temperatures preventing scalding. They shut-off rapidly in the event of a hot or cold supply failure to prevent scalding or thermal shock. TMVs accurately control water temperatures for bathing, showering and hand-washing. They maintain pre-set temperatures-even if water pressure varies when other appliances are used. TMVs can be fitted under baths and basins, be part of shower fittings, or as a feature of exposed hot and cold water mixers. 5.Usage of TMVs Point of use mixing for wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings.6.Installation Precaution: a.All installations should be carried out by a Licensed Professional. b.Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C. c.After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2C. d.The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same. e.If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure. 7.How They Work? Upon use of tempered water, a thermostat in the mixing chamber of the valve senses the outlet temperature. The thermostat automatically positions a seat assembly which controls the flow of hot and cold water supplied to the mixing chamber. If the mixed outlet temperature increases, the thermostat will expand moving the seat assembly to allow the cold water inlet port to open more fully and at the same time restricting the hot water inlet port. Conversely, if the mixed outlet temperature decreases, the thermostat will contract moving the seat assembly to allow the hot water inlet port to open more fully and at the same time restricting the cold water inlet port. In both cases the mixed outlet water temperature is automatically and continually maintained at the preset temperature within the tolerances of the valve. In the event of a cold or hot water supply failure, the seat assembly moves to an extreme position shutting off the hot or cold inlet water port. A mechanical adjustment permits selection of the desired outlet water temperature within range of the valve.8.Installation Precaution:a.All installations should be carried out by a Licensed Professional. b.Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C c.After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2C. d.The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same. e.If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure. j.Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation9.Relationsships between TMVs and Legionella:Legionella is the bacteria responsible for Legionnaires Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacteria and has been found to exist widely in many surface water sources such as; lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water systemIt can find an ideal host environment of warm water temperatures (40-46C), stagnant water areas (storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaires Disease.There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 60C. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries. Shenyan Beixin Energy Saving Equipment Co.,Ltd Contact:Mr.Bob Liu Mobile Ph#:86-13898845136

Условия поставки и упаковка

Packaging Detail: Carton1 piece packaging(mm):150*87*52, small carton10 pcs package(mm):310*245*130, middle carton30 pcs package(mm):470*315*190, big carton Delivery Detail: 5-45days
Порт: Dalian

Условия оплаты

Электронный перевод

Вестерн Юнион

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций