СЕРИЯ HZD КЛАСС 1E Многооборотные электрический клапан АСП

СЕРИЯ HZD КЛАСС 1E Многооборотные электрический клапан АСП

Чанчжоу, Китай
Объем производства:
2000 Набор / Месяц
Чанчжоу, Китай
Компания
86-0519-89856692
Weiping Chen
Контактное лицо

Основные данные

Место происхождения Jiangsu China (Mainland)
Бренд CDF
Номер Модели HZD
Тип Клапаны
SERVICE ENVIRONMENTS AND MAIN TECHNICAL DATA 1.Power supply Power lines: three-phase 380V+5% -10% 50Hz+5% -5% Control linessingle-phase 220V+5% -10% 50Hz+5% -5% Other ratings of voltage and frequency need special order 2.Rating: short time duty, 15 min Life time: 40 years Motor insulationH 3. Normal Service Conditions: Table 1 service environment H1H2H3 Temperature C° -2070-2070-2060 Pressure MPa 00.500.500.5 Relative Humidity % ≤100≤100≤95Accumulated Radiation DoseGy 1.9×1061.9×1060Seismic acceleration,in three direction of X,Y,Zg 666Seismic spectrum Hz 0.2350.2350.235Event Conditions Table 2 Event Conditions LOCAMSLBTemperature C° 135200200 for Transient153200200 for TransientPressure MPa 0.30.22Relative Humidity% 100100For LOCA and MSLB conditions, chemical spray solutions inside containment consist of 2000 ppm boric acid and 0.75% by weight sodium hydroxide to PH ≤1 4. Protection: IP68 GENERAL DESCRIPTION Series HZD electric valve actuators of Class 1E (abbrev. as Class 1E Actuators) are designed to meet the demand of nuclear power stations and are suitable for the two-position operation of globe valves, gate valves, throttle valves and diaphragm valves etc. These actuators are conformed to the following standards: 1) IEEE382-1996 IEEE Standard for Qualification of Actuators for Power Operated Valve Assemblies with Safety-Related Functions for Nuclear Power Plants. idt EJ/T531-2001 Qualification of Actuators for Power Operated Valve Assemblies with Safety-Related Functions for Nuclear Power Plants. 2) EJ/T1022.11-1996 Electric Valve Actuators Used in Pressurized-Water Reactors 3) JB/T8528-1997 Specifications of Normal Type Electric Valve Actuators These actuators are divided into three types according to plant service environment: Type H1: used inside containment, subject to event, radiation and seismic environments (satisfied to Catalog K1 environmental conditions in EJ/T1022.11-96) Type H2: (a) used inside containment, subject to radiation and seismic environments but without event environment; (b) used outside containment, subject to effect of event, radiation and seismic environments (satisfied to Catalog K2 environmental conditions in EJ/T1022.11-96) Type H3: used outside containment, without effect of event and radiation but subject to seismic environments (satisfied to Catalog K3 environmental conditions in EJ/T1022.11-96)

Условия поставки и упаковка

Packaging Detail: Export wooden packing Delivery Detail: 35 days after the signing of the contract
Порт: shanghai

Условия оплаты

Аккредитив

Электронный перевод

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций