Место происхождения |
United States |
Бренд |
Rosemount |
Номер Модели |
3051S |
Best-in-class performance with 0.04% accuracy The Rosemount 3051S delivers cutting edge performance beginning with the SuperModule platform. Among the many advances, Saturn™ sensing technology incorporates a secondary sensor to optimize performance and expand diagnostic capabilities. Industry’s first %-of-reading flow transmitter Innovative design combined with patent-pending manufacturing techniques deliver a 10x performance improvement and a wide flow turndown. Industry’s first 10-year stability under actual process conditions Stability begins with an all-welded, 316L SST hermetically sealed SuperModule which houses the single board electronics, thus eliminating moisture and field contaminant effects. Unprecedented reliability backed by a limited 12-year warranty Further enhance installation practices and advanced diagnostic capabilities with the most reliable platform supported by a 12-year warranty. Certified for use in SIS Applications The 3051S is certified by TÜViT to IEC61508 for single input use in SIL 2 Safety Instrumented Systems and dual input use in SIL 3 Safety Instrumented Systems. SuperModule design platform enables more cost effective installation and maintenance practices A scalable architecture enables direct mounting of the SuperModule for maximum performance and reliability. The flexible remote mount LCD display and interface provides access to all digital communications and diagnostics. Scalable functionality to meet expanding needs From basic process variable generation to advanced PlantWeb™ functionality and highly integrated measurement solutions, the 3051S Series meets every application requirement. PERFORMANCE SPECIFICATIONS For zero-based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange (3051S_C) or 1/2 in.- 14 NPT (3051S_T) process connections, digital trim values set to equal range points. Conformance to specification (±3σ (Sigma)) Technology leadership, advanced manufacturing techniques and statistical process control ensure specification conformance to at least ±3σ. Vibration Effect All Models: Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz 0.21mm displacement peak amplitude / 60-2000 Hz 3g). Housing Style codes 1J, 1K, 1L, 2J Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field with general application or pipeline with low vibration level (10-60 Hz 0.15mm displacement peak amplitude / 60-500 Hz 2g). Power Supply Effect All Models: Less than ±0.005% of calibrated span per volt Electromagnetic Compatibility (EMC) All Models: Meets all relevant requirements of IEC/EN 61326 and NAMUR NE-21. Transient Protection (Option T1) All Models: Meets IEEE C62.41, Category B 6 kV crest (0.5 μs - 100 kHz) 3 kV crest (8 × 20 microseconds) 6 kV crest (1.2 × 50 microseconds) Meets IEEE C37.90.1, Surge Withstand Capability SWC 2.5 kV crest, 1.25 MHz wave form General Specifications: Response Time: < 1 nanosecond Peak Surge Current: 5000 amps to housing Peak Transient Voltage: 100 V dc Loop Impedance: < 25 ohms Applicable Standards: IEC61000-4-4, IEC61000-4-5