Место происхождения |
Henan China (Mainland) |
Бренд |
All Win |
Номер Модели |
MY |
Изоляционный материал |
Резина |
For laying indoors or outdoors, including in the ground, in water even the place with large difference of level. Able to bear a certain mechanical force and pulling force. It is suitable to be installed in the power line with rated voltage from (Uo/U) 3.6/6kV to 26/35kV for power transimission.Earth fault permissible duration: The cables are civided into two categories according to the fault duration when single phase is earthed. The first category:the earth fault duration for each time does not exceed one minute,the accumulated time shall not exceed 125 hours each year. The second category:The earth fault duration for each time is longer and the requirement for cable insulation property is more serious.The maximum rated temperature The maximum operating temperature of conductor shall not exceed 90 centidegree when the cable is used for long period. The temperature of conductor shall not exceed 250 centidegree at short circuit for 5 second. Installation requirement The installation of cable is not limited by the difference of elevation along the route.The ambient temperature should not be below 0centidegree during installation.The permissible bending radius for cable shall be complied with the following regulations: For single-core: R>25(D+d)+/-5% For multi-core: R>15(D+d)+/-5% Where:R-----bending radius(mm) D-----overall dimeter of the cable(mm) d-----diameter of conductor(mm) single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducts.(MT818-1999)1. Usage: This product is the rubber sheath flexible cable series used in coal-mining. It is fit for rated voltage Uo/U 0.38/0.66KV used in coal mining machines installation equipment to connect power supply. It can be shifted as you like. 2. Working temperature: The allowed working temperature of the core is 650C. Its smallest bending radius is six times the sizes of cable diameter. The yellow sheath cable should not be exposed in the sun for long. 3. Model and names Model Name Usage MY-0.38/0.66 Movable Rubber-sheathed flexible cable for mining use. Rated vo1tage 0.38/0.66KV, for power supply connection of various coal-mining equipments. MYP-0.38/0.66 Movable shielded Rubber-sheathed flexible cable for mining use Rated vo1tage 0.38/0.66KV, for power supply connection of various coal-mining equipments. MYP-0.66/1.14 Movable shielded Rubber-sheathed flexible cable for mining u Rated voltage 0.66/1.44KV, under ground power supply connection of various coal-mining equipments. MYQ 0.3/0.5KV Movable light-type rubber-sheathed flexible cable for mining use power connection of mine roadway lighting, conveyor chain and controlling, signal equipments. Core*Nominal section(mm2) Cable outer Dia(mm) Power core Ground core MY-0.38/0.66 MYP-0.38/0.66 Min Max Min Max 3*4 1*4 20.3 23.1 23.7 27.2 3*6 1*6 23.0 26.1 26.1 30.1 3*10 1*10 27.5 31.3 30.9 34.7 3*16 1*10 29.6 33.4 33.0 36.8 3*25 1*16 35.6 39.8 39.0 43.2 3*35 1*16 38.7 42.9 42.1 46.3 3*50 1*16 43.6 47.9 47.1 51.4 3*70 1*25 49.7 54.4 52.4 57.1 0.66/1.14kV flexible cable for coal-mining