пропорциональна термостат

пропорциональна термостат

Шанхай, Китай
Объем производства:
20 Штука / Месяц
Шанхай, Китай
Компания
86-021-33828411
Jack Jiang
Контактное лицо

Основные данные

Место происхождения China (Mainland)
Бренд Smart Control
Номер Модели HL8102
proportional thermostat,0-10VDC output, Function: Detect and Display room temperature Room temperature setting Fahrenheit or Celsius degree display Timing sleep Control On/Off of cooling and heating equipment single speed or three speed fan control Specifications: Set temperature range: 0 - 99.5º C adjustable Accuracy displayed: 0.1º C Accuracy: ± 0.5º C Rated Power: < 1 W Sensor type: NTC Display: LCD Power: AC 24V± 10%, 50Hz/60Hz Output signal: AC 24V× 2 (0.5A resistive), 0 - 10VDC(5mA) / 4 - 20mA (600Ω) Input signal: Dry contact (NO) Dimensions: 86× 86× 23mm (W× H× D) Fixing screw width: 60mm (Standard) Parameter Description Default Range Step 1 Power on status (0: Off; 1: On; 2: Hold) 2 0 - 2 2 Fan speed (0: Single Speed; 1: Three Speed) 1 0 - 1 3 Fan mode (DA; DB) 0 4 Sensor selection (0: Internal; 1: Remote) 1 0 - 1 5 Temperature format (0: Celsius; 1: Fahrenheit) 0 0 - 1 0.1 6 Temperature calibration 0 -20.0--+ 20.0 0.1 7 Minimum setpoint 5°C / 41°F 0 - 99.5 0.5 8 Maximum setpoint 35°C /96°F 0 - 99.5 0.5 9 Dead band (from HL8102E to HL8102K) 2 0 - 10 0.5 10 Heating & Auto sleep setpoint 7°C / 45°F 0 - 99.5 0.5 11 Cooling sleep setpoint 28°C /82°F 0 - 99.5 0.5 12 Comms# (HL8102XN) 1 1 - 32 1 Input Signal Mode 0: Invalid 13 1: Changeover(from HL 8102A to HL8102D) 0 0 - 3 2: thermostat will be sleep without input signal 3: thermostat will be Off without input signal 14 Heating reset time 90 sec. 10 - 300 sec. 10 sec. 15 Cooling reset time 90 sec. 10 - 300 sec. 10 sec. 16 Ports mode (0: Modulation & Floating; 1: On/Off) 0 0 - 1 17 Valve status as turn off (0: Close; 1:Hold; 2: Open ) 0 0 - 2 18 Port1 Modulation direction(0:10V Open; 1:10V Close) 0 0 - 1 19 Port1 Modulation minimum signal 0Bit 0-128Bit(5V/10mA) 0.04V/Bit(0.08mA/Bit) 20 Port1 Modulation proportional 2 1 - 20 0.5 21 Port2 Modulation direction(0:10V Open;1:10V Close) 0 0 - 1 22 Port2 Modulation minimum Signal 0 Bit 0-128Bit(5V/10mA) 0.04V/Bit(0.08mA/Bit) 23 Port2 Modulation proportional 2 1 - 20 0.5 24 Port1 Floating minimum time 1 sec. 1 - 9 sec. 1 sec. 25 Port1 Floating maximum time 30 sec. 10 - 300 sec. 10 sec. 26 Port1 Floating minimum time 1 sec. 1-9 sec. 1 sec. 27 Port1 Floating maximum time 30 sec. 10 - 300 sec. 10 sec. 28 Disable / Enable bypass PID control ( 0: Disable; 1: Enable ) 0 0 - 1 29 Override output value when bypass PID control Display output value when enable PID control 0 - 255 30 Override output value when bypass PID control Display output value when enable PID control 0 - 255 31 Input signal management: 0: Input valid 1: Override Input: open 0 0 - 2 2: Override Input: close 32 Display room temperature or set-point 0: Room temperature 1: Set-Point 0 0 - 1

Условия поставки и упаковка

Порт: Shanghai

Условия оплаты

Аккредитив

Электронный перевод

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций